Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis

被引:222
作者
John, Daniel [1 ]
Buellesfeld, Lutz [1 ]
Yuecel, Seyrani [1 ]
Mueller, Ralf [1 ]
Latsios, Georg [1 ]
Beucher, Harald [1 ]
Gerckens, Ulrich [1 ]
Grube, Eberhard [1 ]
机构
[1] HELIOS Heart Ctr Siegburg, Dept Cardiol Angiol, D-53721 Siegburg, Germany
关键词
calcification; procedural success; transcatheter aortic valve implantation; HIGH-RISK PATIENTS; COMPUTED-TOMOGRAPHY; REPLACEMENT; STENOSIS; QUANTIFICATION; PROGRESSION; CT;
D O I
10.1016/j.jcin.2009.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to assess the influence of amount and distribution of calcifications of the aortic valve and the left ventricular outflow tract on the acute procedural outcome of patients undergoing transcatheter aortic valve implantation (TAVI). Background Transcatheter aortic valve implantation is a new percutaneous technique especially for elderly, high-risk patients with significant aortic valve stenosis (AS). After TAVI, post-interventional paravalvular aortic regurgitations (PAR) can occur, which is believed to be related partially to valve calcifications. Methods We prospectively analyzed 100 symptomatic patients with severe AS scheduled for TAVI with the CoreValve ReValving (Medtronic, Minneapolis, Minnesota) prosthesis. In all patients, a native and contrast-enhanced multislice cardiac computed tomography was performed pre-interventionally. Calcification load of the valve and the adjacent outflow tract was estimated by the Agatston Score (AgS), and the amount and distribution of calcification was semi-quantitatively assessed and graded on a 1 to 4 scale (device "landing zone" calcification score [DLZ-CS]). Aortography was performed to evaluate the PAR pre-interventionally, after initial device release (PAR0) and after termination of the procedure (PAR1). Transthoracic echocardiography was performed 2 weeks after implantation (PAR2). Results The AgS and DLZ-CS showed a significant correlation with the grade of PAR0 (AgS: r = 0.329, p = 0.001; DLZ-CS: r = 0.356, p < 0.001), PAR1 (AgS: r = 0.254, p = 0.011; DLZ-CS: r = 0.240, p = 0.016), and PAR2 (AgS: r = 0.341, p = 0.001; DLZ-CS: r = 0.300, p = 0.002). Both scores (AgS and DLZ-CS) showed a significant positive correlation (r = 0.858, p < 0.001). Conclusions Calcification in the CoreValve device "landing zone" shows a significant positive correlation to PAR after TAVI. Furthermore, the need for "second maneuvers" (i.e., post-dilation after initial device release) can be predicted by these calcification scores (AgS and DLZ-CS). (J Am Coll Cardiol Intv 2010;3:233-43) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:233 / 243
页数:11
相关论文
共 27 条
[1]   Impact of small prosthetic valve size on operative mortality in elderly patients after aortic valve replacement for aortic stenosis: Does gender matter? [J].
Adams, DH ;
Chen, RH ;
Kadner, A ;
Aranki, SF ;
Allred, EN ;
Cohn, LH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (05) :815-822
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   Factors leading to progression of valvular aortic stenosis [J].
Bahler, RC ;
Desser, DR ;
Finkelhor, RS ;
Brener, SJ ;
Youssefi, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (09) :1044-1048
[4]  
Baim DS., 2006, Grossman's cardiac catheterization, angiography, and intervention
[5]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[6]   PROGRESSION OF VALVAR AORTIC-STENOSIS - A LONG-TERM RETROSPECTIVE STUDY [J].
DAVIES, SW ;
GERSHLICK, AH ;
BALCON, R .
EUROPEAN HEART JOURNAL, 1991, 12 (01) :10-14
[7]   Should a bicuspid aortic valve be replaced in the presence of subvalvar or supravalvar aortic stenosis? [J].
Delius, RE ;
Samyn, MM ;
Behrendt, DM .
ANNALS OF THORACIC SURGERY, 1998, 66 (04) :1337-1341
[8]  
Feuchtner GM, 2006, J HEART VALVE DIS, V15, P494
[9]  
GERCKENS U, 2008, PERKUTANE AORTENKLAP
[10]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76