Optimization of transmission and emission scan duration in 3D whole-body PET

被引:14
作者
Beyer, T [1 ]
Kinahan, PE [1 ]
Townsend, DW [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, PET Facil, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.656442
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Whole-body PET imaging is being increasingly used to identify and localize malignant disease remote from the site of the primary tumour. Patients are typically scanned at multiple contiguous bed positions over an axial length of 75-100 cm. Ideally, for oncology patients, the total scan duration should not exceed about an hour and therefore only 5-10 minutes of imaging can be performed at each bed position. To minimize the total scan duration, the transmission scan is often omitted and the emission scan reconstructed without attenuation correction. However, whole-body scans reconstructed without attenuation are non-quantitative and can lead to incorrect diagnoses, particularly for tumours located deep within the body. We have performed a series of torso phantom measurements on a 3D PET scanner (ECAT ART) to investigate the optimal partition of scan time between the emission and transmission scans for a fixed total scan duration. We find that 20%-40% of the total scan time should be dedicated to the transmission acquisition to minimize noise in the attenuation-corrected image. The optimal partition depends on the method of calculating the attenuation correction factors and on the reconstruction algorithm.
引用
收藏
页码:2400 / 2407
页数:8
相关论文
共 21 条
[1]   ECAT ART - A continuously rotating PET camera: Performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department [J].
Bailey, DL ;
Young, H ;
Bloomfield, PM ;
Meikle, SR ;
Glass, D ;
Myers, MJ ;
Spinks, TJ ;
Watson, CC ;
Luk, P ;
Peters, AM ;
Jones, T .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (01) :6-15
[2]  
BARRETT HH, 1981, RADIOLOGICAL IMAGING, V2
[3]  
CHAN MT, 1996, IEEE MIC 1996 AN M9
[4]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[5]   A FACTORIZATION METHOD FOR THE 3D X-RAY TRANSFORM [J].
DEFRISE, M .
INVERSE PROBLEMS, 1995, 11 (05) :983-994
[6]  
DEKEMP RA, 1992, MED PHYS, V21, P1191
[7]  
Engel H, 1996, J NUCL MED, V37, P441
[8]   HYBRID POISSON POLYNOMIAL OBJECTIVE FUNCTIONS FOR TOMOGRAPHIC IMAGE-RECONSTRUCTION FROM TRANSMISSION SCANS [J].
FESSLER, JA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (10) :1439-1450
[9]   CANCER-DETECTION WITH WHOLE-BODY PET USING 2-[F-18]FLUORO-2-DEOXY-D-GLUCOSE [J].
HOH, CK ;
HAWKINS, RA ;
GLASPY, JA ;
DAHLBOM, M ;
TSE, NY ;
HOFFMAN, EJ ;
SCHIEPERS, C ;
CHOI, Y ;
REGE, S ;
NITZSCHE, E ;
MADDAHI, J ;
PHELPS, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) :582-589
[10]   Estimation of the noise-contributions from blank, transmission and emission scans in PET [J].
Holm, S ;
Toft, P ;
Jensen, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (04) :2285-2291