Clinical results of implantation of the Chirila keratoprosthesis in rabbits

被引:40
作者
Hicks, CR [1 ]
Chirila, TV [1 ]
Clayton, AB [1 ]
Fitton, JH [1 ]
Vijayasekaran, S [1 ]
Dalton, PD [1 ]
Lou, X [1 ]
Platten, S [1 ]
Ziegelaar, B [1 ]
Hong, Y [1 ]
Crawford, GJ [1 ]
Constable, IJ [1 ]
机构
[1] Lions Eye Inst, Perth, WA 6009, Australia
关键词
D O I
10.1136/bjo.82.1.18
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Aims/background-An ideal keratoprosthesis (KPro) would closely resemble a donor corneal button in terms of its surgical handling, optics, and capacity to heal with host tissue in order to avoid many of the complications associated with the KPros which are currently in clinical use, This steady was carried out to assess the long term clinical outcomes on implantation of the core and skirt poly(2-hydroxyethyl methacrylate) KPro in animals. Methods-20 KPros were made and implanted as full thickness corneal replacements into rabbits and followed for up to 21 months to date. Results-80% of the prostheses ha-rie been retained, with a low incidence Of complications such as cataract, glaucoma, and retroprosthetic membrane formation which are frequently associated with KPro surgery. Conclusions-KPros of this type may offer promise in the treatment of patients for whom penetrating keratoplasty with donor material carries a poor prognosis. Refinement of the KPro and further animal trials, including implantation into abnormal corneas, are however mandatory before human implantation; could be planned.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 41 条
[1]
BARBER JC, 1980, INVEST OPHTH VIS SCI, V19, P182
[2]
CLINICAL-RESULTS OF HYDROGEL LENS IMPLANTATION [J].
BARRETT, GD ;
CONSTABLE, IJ ;
STEWART, AD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (06) :623-631
[3]
DYSTROPHIC CALCIFICATION OF SILICONE SCLERAL BUCKLING IMPLANT MATERIALS [J].
BROCKHURST, RJ ;
WARD, RC ;
LOU, P ;
ORMEROD, D ;
ALBERT, D .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 115 (04) :524-529
[4]
BUCHER PJM, 1995, ARCH OPHTHALMOL-CHIC, V113, P1421
[5]
Cardona H, 1991, Refract Corneal Surg, V7, P468
[6]
CERNY E, 1970, SCRIPTA MED, V43, P63
[7]
HYDROPHILIC SPONGES BASED ON 2-HYDROXYETHYL METHACRYLATE .1. EFFECT OF MONOMER MIXTURE COMPOSITION ON THE PORE-SIZE [J].
CHIRILA, TV ;
CHEN, YC ;
GRIFFIN, BJ ;
CONSTABLE, IJ .
POLYMER INTERNATIONAL, 1993, 32 (03) :221-232
[8]
Production of neocollagen by cells invading hydrogel sponges implanted in the rabbit cornea [J].
Chirila, TV ;
ThompsonWallis, DE ;
Crawford, GJ ;
Constable, IJ ;
Vijayasekaran, S .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1996, 234 (03) :193-198
[9]
POLY(2-HYDROXYETHYL METHACRYLATE) SPONGES AS IMPLANT MATERIALS - INVIVO AND INVITRO EVALUATION OF CELLULAR INVASION [J].
CHIRILA, TV ;
CONSTABLE, IJ ;
CRAWFORD, GJ ;
VIJAYASEKARAN, S ;
THOMPSON, DE ;
CHEN, YC ;
FLETCHER, WA ;
GRIFFIN, BJ .
BIOMATERIALS, 1993, 14 (01) :26-38
[10]
INTERPENETRATING POLYMER NETWORK (IPN) AS A PERMANENT JOINT BETWEEN THE ELEMENTS OF A NEW-TYPE OF ARTIFICIAL CORNEA [J].
CHIRILA, TV ;
VIJAYASEKARAN, S ;
HORNE, R ;
CHEN, YC ;
DALTON, PD ;
CONSTABLE, IJ ;
CRAWFORD, GJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (06) :745-753