Novel mercuric iodide polycrystalline nuclear particle counters

被引:29
作者
Schieber, M [1 ]
Zuck, A
Braiman, M
Nissenbaum, J
Turchetta, R
Dulinski, W
Husson, D
Riester, JL
机构
[1] Hebrew Univ Jerusalem, IL-91904 Jerusalem, Israel
[2] Sandia Natl Labs, Livermore, CA 94550 USA
[3] ULP, LEPSI, IN2P3, Strasbourg, France
关键词
imaging; mercuric iodide; radiation detectors;
D O I
10.1109/23.650865
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Polycrystalline mercuric iodide nuclear radiation detectors have been produced in a novel technology, Unlike the normal single-crystal technology, there is no intrinsic limit to the surface on which these detectors can be produced, Detectors with areas up to about 1.5 cm(2), thicknesses from 30 to 600 mu m, and with single electrodes as well as microstrip and pixel contacts have been fabricated and successfully tested with photons in the range of 40-660 keV, beta particle's emitted from a Sr-Y source, and high energy (100 GeV) muons, Results on both charge collection and counting efficiency are reported as well as some very preliminary imaging results, The experimental results on charge collection have been compared with simulation, and a combined mu tau product 10(-7) cm(2)/V for electrons has been estimated.
引用
收藏
页码:2571 / 2575
页数:5
相关论文
共 6 条
[1]   A submicron precision silicon telescope for beam test purposes [J].
Colledani, C ;
Dulinski, W ;
Turchetta, R ;
Djama, F ;
Rudge, A ;
Weilhammer, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (03) :379-384
[2]   Castor 1.0, a VLSI analog-digital circuit for pixel imaging applications [J].
Colledani, C ;
Comes, G ;
Dulinski, W ;
Hu, Y ;
Loddo, F ;
Turchetta, R ;
Bonvicini, V ;
Castelli, E ;
Pontoni, D ;
Prest, M ;
Rashevsky, A ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03) :435-442
[3]   CASTOR a VLSI CMOS mixed analog-digital circuit for low noise multichannel counting applications [J].
Comes, G ;
Loddo, F ;
Hu, Y ;
Kaplon, J ;
Ly, F ;
Turchetta, R ;
Bonvicini, V ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) :440-445
[4]  
SCHIEBER M, 1996, IN PRESS P 5 INT C A
[5]  
Schlesinger T.E., 1995, SEMICONDUCTORS ROOM
[6]   VIKING, A CMOS LOW-NOISE MONOLITHIC 128 CHANNEL FRONTEND FOR SI-STRIP DETECTOR READOUT [J].
TOKER, O ;
MASCIOCCHI, S ;
NYGARD, E ;
RUDGE, A ;
WEILHAMMER, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (03) :572-579