Optimal Design of Multiple-Channel RF Pulses Under Strict Power and SAR Constraints

被引:60
作者
Brunner, David O. [1 ]
Pruessmann, Klaas P. [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
parallel transmission; pulse design; RF safety; transmit array; Transmit SENSE; B1; non-uniformity; ultra-high-field MRI; PARALLEL EXCITATION; LEAST-SQUARES; RECONSTRUCTION; ARRAY; LANCZOS; MRI;
D O I
10.1002/mrm.22330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Parallel radio frequency transmission has recently been explored as a means of tailoring the spatial response of MR excitation. In particular, parallel transmission is increasingly used to accelerate radio frequency pulses that rely on time-varying gradient fields to achieve selectivity in multiple dimensions. The design of the underlying multiple-channel radio frequency waveforms is mostly based on regularized least-squares optimization in close analogy with image reconstruction in parallel imaging. However, this analogy has important limitations. Unlike image reconstruction, the design of radio frequency waveforms is subject to multiple strict constraints, which arise from technical power limits, as well as safety limits on local and global energy deposition in vivo. To optimize excitation profiles under such strict constraints, it is proposed to depart from the regularization strategy and rely on semidefinite programming instead. To render this approach fast, it is performed in a reduced search space, which is obtained by initial Lanczos iteration. The proposed algorithm is demonstrated to enable efficient pulse optimization within exactly the given constraints, including local specific absorption rate limits for multiple compartments. It is also shown that the proposed approach readily accommodates advanced forward models of the excitation process, including the effects of local off-resonance and transverse relaxation. Magn Reson Med 63:1280-1291, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1280 / 1291
页数:12
相关论文
共 46 条
[1]
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]
[Anonymous], P CACSD C TAIP
[3]
BARMET C, 2005, P INT SOC MAG RES ME
[4]
Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[5]
Brunner D.O., 2007, Proc. 15th Ann. Meet. Intl. Soc. Mag. Reson. Med, P1690
[6]
BRUNNER DO, 2008, P INT SOC MAG RES ME, P635
[7]
Froehlich J, 2007, IEEE MTT S INT MICR, P2208
[8]
Golub G.H., 1996, MATRIX COMPUTATIONS, V3rd, P694
[9]
QUADRATICALLY CONSTRAINED LEAST-SQUARES AND QUADRATIC PROBLEMS [J].
GOLUB, GH ;
VONMATT, U .
NUMERISCHE MATHEMATIK, 1991, 59 (06) :561-580
[10]
GRAESSLIN I, 2006, P INT SOC MAG RES ME, P2470