Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging

被引:108
作者
Philip, J [1 ]
Carlsson, K
机构
[1] Royal Inst Technol, Dept Math, SE-10044 Stockholm, Sweden
[2] Royal Inst Technol, Stockholm Ctr Phys Astron & Biotechnol, SE-10044 Stockholm, Sweden
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 2003年 / 20卷 / 02期
关键词
D O I
10.1364/JOSAA.20.000368
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We deduce the signal-to-noise ratio for fluorescence lifetime imaging when using frequency-domain methods. We assume mono-exponential decay and quantum-noise-limited performance. The results are compared with Monte Carlo simulations with good agreement. We also compare our results with previous investigations of time-domain methods for fluorescence lifetime imaging. For a given number of detected photons, we find that frequency-domain and time-domain methods are equally good. The correct choice of detection technique and its parameters is important for obtaining good results. (C) 2003 Optical Society of America.
引用
收藏
页码:368 / 379
页数:12
相关论文
共 30 条
[1]   AN ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR THE EVALUATION OF SINGLE EXPONENTIAL DECAYS [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :30-33
[2]   Fluorescence lifetime measurements in confocal microscopy of neurons labeled with multiple fluorophores [J].
Brismar, H ;
Ulfhake, B .
NATURE BIOTECHNOLOGY, 1997, 15 (04) :373-377
[3]   Double-pulse fluorescence lifetime measurements [J].
Buist, AH ;
Muller, M ;
Gijsbers, EJ ;
Brakenhoff, GJ ;
Sosnowski, TS ;
Norris, TB ;
Squier, J .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 186 :212-220
[4]   FLUORESCENCE LIFETIME IMAGING USING A CONFOCAL LASER SCANNING MICROSCOPE [J].
BUURMAN, EP ;
SANDERS, R ;
DRAAIJER, A ;
GERRITSEN, HC ;
VANVEEN, JJF ;
HOUPT, PM ;
LEVINE, YK .
SCANNING, 1992, 14 (03) :155-159
[5]  
Carlsson K, 1998, J MICROSC-OXFORD, V191, P119, DOI 10.1046/j.1365-2818.1998.00362.x
[6]   Confocal pH imaging of microscopic specimens using fluorescence lifetimes and phase fluorometry: influence of parameter choice on system performance [J].
Carlsson, K ;
Liljeborg, A ;
Andersson, RM ;
Brismar, H .
JOURNAL OF MICROSCOPY-OXFORD, 2000, 199 (02) :106-114
[7]   Theoretical investigation of the signal-to-noise ratio for different fluorescence lifetime imaging techniques [J].
Carlsson, K ;
Philip, J .
OPTICAL DIAGNOSTICS OF LIVING CELLS V, 2002, 4622 :70-78
[8]   Confocal fluorescence microscopy using spectral and lifetime information to simultaneously record four fluorophores with high channel separation [J].
Carlsson, K ;
Liljeborg, A .
JOURNAL OF MICROSCOPY, 1997, 185 :37-46
[9]   Multiple time-gate module for fluorescence lifetime imaging [J].
de Grauw, CJ ;
Gerritsen, HC .
APPLIED SPECTROSCOPY, 2001, 55 (06) :670-678
[10]  
Draaijer A., 1995, P491