How, why, and when may atrial defibrillation find a specific role in implantable devices? A clinical viewpoint

被引:7
作者
Boriani, Giuseppe
Diemberger, Igor
Biffi, Mauro
Martignani, Cristian
Ziacchi, Matteo
Bertini, Matteo
Valzania, Cinzia
Bronzetti, Gabriele
Rapezzi, Claudio
Branzi, Angelo
机构
[1] Univ Bologna, Inst Cardiol, Policlin S Orsola Malpighi, Azienda Osped S Orsola Malpighi, I-40138 Bologna, Italy
[2] Univ Bologna, Dept Pediat Cardiol, Policlin S Orsola Malpighi, Azienda Osped S Orsola Malpighi, I-40138 Bologna, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2007年 / 30卷 / 03期
关键词
atrial defibrillator; atrial fibrillation; implantable cardioverter defibrillator; heart failure; cardiac resynchronization therapy; hybrid therapy;
D O I
10.1111/j.1540-8159.2007.00685.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This viewpoint article discusses the potential for incorporation of atrial defibrillation capabilities in modern multi-chamber devices. In the late 1990s, the possibility of using shock-only therapy to treat selected patients with recurrent atrial fibrillation (AF) was explored in the context of the stand-alone atrial defibrillator. The failure of this strategy can be attributed to the technical limitations of the stand-alone device, low tolerance of atrial shocks, difficulties in patient selection, a lack of predictive knowledge about the evolution of AF, and, last but not least, commercial considerations. An open question is how atrial defibrillation capability may now assume a specific new role in devices implanted for sudden death prevention or cardiac resynchronization. For patients who already have indications for implantable devices, device-based atrial defibrillation appears attractive as a "backup" option for managing AF when preventive pharmacological/electrical measures fail. This and several other personalized hybrid therapeutic approaches await exploration, though assessment of their efficacy is methodologically challenging. Achievement of acceptance by patients is an essential premise for any updated atrial defibrillation strategy. Strategies that are being investigated to improve patient tolerance include waveform shaping, pharmacologic modulation of pain, and patient-activated defibrillation (patients might also perceive the problem of discomfort somewhat differently in the context of a backup therapy). The economic impact of implementing atrial defibrillation features in available devices is progressively decreasing, and financial feasibility need not be a major issue. Future studies should examine clinically relevant outcomes and not be limited (as occurred with stand-alone defibrillators) to technical or other soft endpoints.
引用
收藏
页码:422 / 433
页数:12
相关论文
共 91 条
  • [1] Efficacy of pacing therapies for treating atrial tachyarrhythmias in patients with ventricular arrhythmias receiving a dual-chamber implantable cardioverter defibrillator
    Adler, SW
    Wolpert, C
    Warman, EN
    Musley, SK
    Koehler, JL
    Euler, DE
    [J]. CIRCULATION, 2001, 104 (08) : 887 - 892
  • [2] [Anonymous], 2001, CIRCULATION, V104, P2118
  • [3] Structural changes of atrial myocardium due to sustained atrial fibrillation in the goat
    Ausma, J
    Wijffels, M
    Thone, F
    Wouters, L
    Allessie, M
    Borgers, M
    [J]. CIRCULATION, 1997, 96 (09) : 3157 - 3163
  • [4] The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators
    Best, PJM
    Hayes, DL
    Stanton, MS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 79 - 85
  • [5] Effects of oral propafenone administration before electrical cardioversion of chronic atrial fibrillation: A placebo-controlled study
    Bianconi, L
    Mennuni, M
    Lukic, V
    Castro, A
    Chieffi, M
    Santini, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) : 700 - 706
  • [6] Improving the acceptability of the atrial defibrillator: Patient-activated cardioversion versus automatic night cardioversion with and without sedation (ADSAS 2)
    Boodhoo, L
    Mitchell, A
    Ujhelyi, M
    Sulke, N
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (07): : 910 - 917
  • [7] Transvenous internal cardioversion for atrial fibrillation: a randomized study on defibrillation threshold and tolerability of asymmetrical compared with symmetrical shocks
    Boriani, G
    Biffi, M
    Zannoli, R
    Branzi, A
    Magnani, B
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 71 (01) : 63 - 69
  • [8] Neurohormones and inflammatory mediators in patients with heart failure undergoing cardiac resynchronization therapy: Time courses and prediction of response
    Boriani, G
    Regoli, F
    Saporito, D
    Martignani, C
    Toselli, T
    Biffi, M
    Francolini, G
    Diemberger, I
    Bacchi, L
    Rapezzi, C
    Ferrari, R
    Branzi, A
    [J]. PEPTIDES, 2006, 27 (07) : 1776 - 1786
  • [9] The epidemiological burden of atrial fibrillation: a challenge for clinicians and health care systems
    Boriani, G
    Diemberger, I
    Martignani, C
    Biffi, M
    Branzi, A
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (08) : 893 - 894
  • [10] Cardiac resynchronization therapy: Effects on left and right ventricular ejection fraction during exercise
    Boriani, G
    Fallani, F
    Martignani, C
    Biffi, M
    Saporito, D
    Greco, C
    Ziacchi, M
    Levorato, M
    Pontone, G
    Valzania, C
    Diemberger, I
    Franchi, R
    Branzi, A
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 : S11 - S14