ZrO2 three-unit fixed partial dentures:: comparison of failure load before and after exposure to a mastication simulator

被引:53
作者
Att, W.
Grigoriadou, M.
Strub, J. R.
机构
[1] Univ Freiburg, Fac Dent, Dept Prosthodont, D-79106 Freiburg, Germany
[2] Univ Calif Los Angeles, Sch Dent, Weintraub Ctr Reconstruct Biotechnol, Los Angeles, CA 90024 USA
关键词
all-ceramic; Y-TZP zirconia; fixed partial denture; failure load; mastication simulator;
D O I
10.1111/j.1365-2842.2006.01705.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the failure load of different zirconia-based all-ceramic fixed partial dentures (FPD) before and after artificial aging. Forty-eight zirconia frameworks for three-unit FPDs were fabricated using different manufacturing systems [(DCS), Procera (Nobel Biocare) and Cerec inLab (Sirona)], veneered using Vita VM9 (Vita Zahnfabrik) opaque ceramic and conventionally cemented on human teeth. The restorations were divided according to the system used for manufacturing the frameworks into three groups of 16 specimens each (DCS, Procera and Vita YZ-Cerec). Half of each group was artificially aged through dynamic loading and thermal cycling, whereas, the other half was not subjected to artificial aging. Subsequently, all specimens were loaded occlusally until fracture occurred using a universal testing machine. Pair-wise Wilcoxon rank tests were performed to test for differences in failure loads at a statistical significance level of 0.05. All specimens subjected to artificial aging survived with no failures. The median (IQR = x(0.25)-x(0.75)) failure loads (N) before and after artificial aging were, respectively, as follows: group DCS, 2131 (1948-2239) and 1797 (1590-2074); group Procera, 1684 (1615-1873) and 1394 (1275-1495); and group Vita YZ-Cerec, 1845 (1621-1923) and 1625 (1521-1747). No significant differences were found for comparisons between different groups before artificial aging. After artificial aging, group Procera showed significantly smaller values than group DCS (P = 0.042). All tested restorations have the potential to withstand occlusal forces applied in the posterior region and can therefore represent interesting alternatives to replace metal-ceramic restorations. Further assessments are needed before recommending these restorations for daily practice.
引用
收藏
页码:282 / 290
页数:9
相关论文
共 52 条
[1]   Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure [J].
Ardlin, BI .
DENTAL MATERIALS, 2002, 18 (08) :590-595
[2]   Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) :380-386
[3]  
ATT W, 2007, IN PRESS ACTA ODONTO
[4]  
Bates J F, 1976, J Oral Rehabil, V3, P57, DOI 10.1111/j.1365-2842.1976.tb00929.x
[5]   LONG-TERM IN-VIVO AND IN-VITRO AGING OF A ZIRCONIA CERAMIC USED IN ORTHOPAEDY [J].
CALES, B ;
STEFANI, Y ;
LILLEY, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05) :619-624
[6]   What future for zirconia as a biomaterial? [J].
Chevalier, J .
BIOMATERIALS, 2006, 27 (04) :535-543
[7]   Critical effect of cubic phase on aging in 3 mol% yttria-stabilized zirconia ceramics for hip replacement prosthesis [J].
Chevalier, J ;
Deville, S ;
Münch, E ;
Jullian, R ;
Lair, F .
BIOMATERIALS, 2004, 25 (24) :5539-5545
[8]  
Chitmongkolsuk Somsak, 2002, Eur J Prosthodont Restor Dent, V10, P15
[9]   MECHANICAL-PROPERTIES AND SHORT-TERM INVIVO EVALUATION OF YTTRIUM-OXIDE-PARTIALLY-STABILIZED ZIRCONIA [J].
CHRISTEL, P ;
MEUNIER, A ;
HELLER, M ;
TORRE, JP ;
PEILLE, CN .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (01) :45-61
[10]   FUNCTIONAL OCCLUSAL FORCES - INVESTIGATION BY TELEMETRY [J].
DEBOEVER, JA ;
MCCALL, WD ;
HOLDEN, S ;
ASH, MM .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (03) :326-333