Retroperitoneoscopic and laparoscopic suturing: Tips and strategies for improving efficiency

被引:35
作者
Frede, T
Stock, C
Rassweiler, JJ
Alken, P
机构
[1] Klinikum heilbron, Dept Urol, D-74078 Heilbronn, Germany
[2] Univ Hosp Mannheim, Dept Urol, Mannheim, Germany
关键词
D O I
10.1089/end.2000.14.905
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: The difficulties of minimally invasive reconstructive surgery, laparoscopically or retroperitoneoscopically, are caused by spatial limitation and fixed trocar positions and, therefore, restricted movement and handling of the instruments. In addition to a standardization of the technique, continual training, and improved instrument technologies, optimization of the geometry of reconstructive surgery, such as angles and distances between the working ports or the camera and needle position, are imperative to providing an optimal clinical performance. Materials and Methods: After designing a standardized suturing technique and conducting an experimental analysis of the geometric factors important in reconstructive surgery, we transferred these results to our clinical setting. A series of 116 reconstructive laparoscopic and retroperitoneoscopic procedures (nephropexy, pyeloplasty, bladder neck suspension, and radical prostatectomy) were analyzed according to the technical realization and quality of reconstruction. Trocar and table positions were adjusted according to our preliminary results, as were the position of the instruments and camera. Results: The trocar and instrument positions are critical for the clinical outcome of reconstructive surgery. Continual training in a standardized suturing technique, together with the clinical application of the important geometric rules, can reduce surgery time by 50%, The time required for suturing single knots could be decreased even more: as much as 75%, thus ensuring efficient and safe reconstructive surgery. Conclusion: Reconstructive procedures such as pyeloplasty or radical prostatectomy can be standardized and performed in an acceptable amount of time with adequate quality when adhering to a standardized technique and the important geometric rules. Improved performance in terms of time and quality will increase the acceptance of these procedures, which can help to solve the problem associated with a low total number of indications for laparoscopy and retroperitoneoscopy.
引用
收藏
页码:905 / 913
页数:9
相关论文
共 49 条
[1]  
Andrews S M, 1994, Endosc Surg Allied Technol, V2, P62
[2]   Minimally invasive direct coronary artery bypass grafting: Experimental and clinical experiences [J].
Arom, KV ;
Emery, RW ;
Nicoloff, DM ;
Flavin, TF ;
Emery, AM .
ANNALS OF THORACIC SURGERY, 1997, 63 (06) :S48-S52
[3]   FIBRIN GLUE [J].
ATRAH, HI .
BRITISH MEDICAL JOURNAL, 1994, 308 (6934) :933-934
[4]  
Bowyer DW, 1993, MINIMAL INVASIV THER, V4, P165
[5]   LAPAROSCOPIC UROLOGY - PAST, PRESENT, AND FUTURE [J].
CLAYMAN, RV ;
KAVOUSSI, LR .
WORLD JOURNAL OF SURGERY, 1993, 17 (01) :57-62
[6]   LAPAROSCOPIC NEPHRECTOMY - INITIAL CASE-REPORT [J].
CLAYMAN, RV ;
KAVOUSSI, LR ;
SOPER, NJ ;
DIERKS, SM ;
MERETYK, S ;
DARCY, MD ;
ROEMER, FD ;
PINGLETON, ED ;
THOMSON, PG ;
LONG, SR .
JOURNAL OF UROLOGY, 1991, 146 (02) :278-282
[7]   AN INITIAL COMPARATIVE-STUDY OF 2 TECHNIQUES OF LAPAROSCOPIC COLONIC ANASTOMOSIS AND MESENTERIC DEFECT CLOSURE [J].
COHEN, SM ;
CLEM, MF ;
WEXNER, SD ;
JAGELMAN, DG .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (02) :130-134
[8]  
Cornier E., 1994, Journal de Gynecologie Obstetrique et Biologie de la Reproduction, V23, P378
[9]   SUTURELESS END-TO-END BOWEL ANASTOMOSIS USING ND-YAG AND WATER-SOLUBLE INTRALUMINAL STENT [J].
COSTELLO, AJ ;
JOHNSON, DE ;
CROMEENS, DM ;
WISHNOW, KI ;
VONESCHENBACH, AC ;
RO, JY .
LASERS IN SURGERY AND MEDICINE, 1990, 10 (02) :179-184
[10]   LAPAROSCOPIC ANTIREFLUX SURGERY AND REPAIR OF HIATAL-HERNIA [J].
CUSCHIERI, A .