Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase dispersion-HPLC

被引:78
作者
Aguilar-Arteaga, K. [1 ]
Rodriguez, J. A. [1 ]
Miranda, J. M. [1 ,2 ]
Medina, J. [3 ]
Barrado, E. [3 ]
机构
[1] Univ Autonoma Estado Hidalgo, Ctr Invest Quim, Pachuca 42074, Hgo, Mexico
[2] Univ Santiago Compostela, Fac Vet, Dept Quim Analit Nutr & Bromatol, Lugo 27002, Spain
[3] Univ Valladolid, Dept Quim Analit, QUIANE, E-47005 Valladolid, Spain
关键词
Magnetic-MSPD; NSAIDs; HPLC; Magnetic separation; ACIDIC PHARMACEUTICALS; WATER; EXTRACTION; MICROEXTRACTION;
D O I
10.1016/j.talanta.2009.08.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A series of supports functionalized with different alkyl chains and covered with magnetite were synthesized, characterized and applied in the sample pre-concentration of four non-steroidal anti-inflammatory drugs (acetaminophen, naproxen, diclofenac and ibuprofen) contained in wastewater samples. The general methodology involved magnetic solid phase dispersion followed by the analysis by high-performance liquid chromatography with ultraviolet detection. The magnetic supports were initially dispersed in the samples with the aid of Triton X-100, then supports were magnetically isolated and the analytes were eluted with methanol. Finally the extract was injected into the HPLC system. The highest recovery percentage (>90%) was obtained with the support containing octyl chains (C8) at pH 3. The lowest limits of detection achieved ranged within 1-2 mu g L-1 with repeatability (expressed as RSD) below 5% in all cases. The method was applied in the analysis of wastewater samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1152 / 1157
页数:6
相关论文
共 16 条
[1]   High-performance liquid magneto-chromatograph [J].
Barrado, E. ;
Rodriguez, J. A. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) :189-193
[2]   Optimization of the operational variables of a medium-scale reactor for metal-containing wastewater purification by ferrite formation [J].
Barrado, E ;
Prieto, F ;
Vega, M ;
Fernández-Polanco, F .
WATER RESEARCH, 1998, 32 (10) :3055-3061
[3]   Application of porous membrane-protected micro-solid-phase extraction combined with HPLC for the analysis of acidic drugs in wastewater [J].
Basheer, Chanbasha ;
Chong, Han Guang ;
Hii, Toh Ming ;
Lee, Hian Kee .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6845-6850
[4]   New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aromatic hydrocarbons in bivalves [J].
Campins-Falco, P. ;
Verdu-Andres, J. ;
Sevillano-Cabeza, A. ;
Molins-Legua, C. ;
Herraez-Hernandez, R. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1211 (1-2) :13-21
[5]   In vitro assessment of modes of toxic action of pharmaceuticals in aquatic life [J].
Escher, BI ;
Bramaz, N ;
Eggen, RIL ;
Richter, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (09) :3090-3100
[6]   Effects of pH and cationic and nonionic surfactants on the adsorption of pharmaceuticals to a natural aquifer material [J].
Hari, AC ;
Paruchuri, RA ;
Sabatini, DA ;
Kibbey, TCG .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (08) :2592-2598
[7]   Occurrence of acidic pharmaceuticals in raw and treated sewages and in receiving waters [J].
Lindqvist, N ;
Tuhkanen, T ;
Kronberg, L .
WATER RESEARCH, 2005, 39 (11) :2219-2228
[8]   Analysis of estrogens in water by magnetic octadecylsilane particles extraction and sweeping micellar electrokinetic chromatography [J].
Liu, Yaling ;
Jia, Li .
MICROCHEMICAL JOURNAL, 2008, 89 (01) :72-76
[9]   Application of liquid chromatography/quadrupole-linear ion trap mass spectrometry and time-of-flight mass spectrometry to the determination of pharmaceuticals and related contaminants in wastewater [J].
Martinez Bueno, Maria Jesus ;
Aguera, Ana ;
Jose Gomez, Maria ;
Dolores Hernando, Maria ;
Garcia-Reyes, Juan Francisco ;
Fernandez-Alba, Amadeo R. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9372-9384
[10]  
*MIN SAN CONS, 2005, REAL FARM ESP