A prospective approach to correct for inter-image head rotation in FMRI

被引:50
作者
Lee, CC [1 ]
Grimm, RC [1 ]
Manduca, A [1 ]
Felmlee, JP [1 ]
Ehman, RL [1 ]
Riederer, SJ [1 ]
Jack, CR [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Radiol, Rochester, MN 55905 USA
关键词
functional magnetic resonance imaging; navigator echoes; motion correction; real-time MRI;
D O I
10.1002/mrm.1910390210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Global head motion occurring between successive image acquisitions during a functional MRI time series can corrupt the signal of physiologic brain activation, potentially invalidating interpretation of the final activation map from that particular fMRI time series, By approximating the head as a rigid body, multiaxial global head motion can be decomposed into orthogonal linear and rotational components, This paper describes a method using orbital navigator echoes to provide prospective correction for both through-plane and in-plane inter-image head rotation in functional MRI, The dynamic detection and correction of rotation can be performed in <100 ms, Phantom experiments demonstrate accurate correction of rotational motion over a range of +/-0.36 degrees to +/-12 degrees., Imaging studies in volunteers document the feasibility of real-time prospective correction of rotational motion in vivo., Using a modified receiver operating characteristic method, motion-corrected functional MRI sensorimotor studies incorporating deliberate head rotations are shown to be superior to functional MRI time series acquired under similar conditions but without motion correction.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 25 条
  • [1] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [2] Reduction of physiological fluctuations in fMRI using digital filters
    Biswal, B
    DeYoe, EA
    Hyde, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 107 - 113
  • [3] Statistical methods of estimation and inference for functional MR image analysis
    Bullmore, E
    Brammer, M
    Williams, SCR
    Rabehesketh, S
    Janot, N
    David, A
    Mellers, J
    Howard, R
    Sham, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) : 261 - 277
  • [4] LOCALIZATION OF BRAIN-FUNCTION USING MAGNETIC-RESONANCE-IMAGING
    COHEN, MS
    BOOKHEIMER, SY
    [J]. TRENDS IN NEUROSCIENCES, 1994, 17 (07) : 268 - 277
  • [5] AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
    Cox, RW
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1996, 29 (03): : 162 - 173
  • [6] Cardiac magnetic resonance fluoroscopy
    Debbins, JP
    Riederer, SJ
    Rossman, PJ
    Grimm, RC
    Felmlee, JP
    Breen, JF
    Ehman, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 588 - 595
  • [7] Movement-related effects in fMRI time-series
    Friston, KJ
    Williams, S
    Howard, R
    Frackowiak, RSJ
    Turner, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) : 346 - 355
  • [8] ORBITAL NAVIGATOR ECHOES FOR MOTION MEASUREMENTS IN MAGNETIC-RESONANCE-IMAGING
    FU, ZW
    WANG, Y
    GRIMM, RC
    ROSSMAN, PJ
    FELMLEE, JP
    RIEDERER, SJ
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) : 746 - 753
  • [9] GRIMM RC, 1997, P 5 ANN M ISMRM VANC, P1899
  • [10] ARTIFACTS DUE TO STIMULUS CORRELATED MOTION IN FUNCTIONAL IMAGING OF THE BRAIN
    HAJNAL, JV
    MYERS, R
    OATRIDGE, A
    SCHWIESO, JE
    YOUNG, IR
    BYDDER, GM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) : 283 - 291