Quartz crystal microbalance sensor deposited with Langmuir-Blodgett films of functionalized polythiophenes and application to heavy metal ions analysis

被引:65
作者
Ng, SC [1 ]
Zhou, XC
Chen, ZK
Miao, P
Chan, HSO
Li, SFY
Fu, P
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 119260, Singapore
[2] Natl Univ Singapore, Inst Mat Res & Engn, Singapore 119260, Singapore
关键词
D O I
10.1021/la970296v
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Two novel functionalized polythiophenes, poly[3-(6-hydroxyhexyl)thiophene] and poly(3-octanethio-2,2'-bithiophene), were used as selective coating materials for quartz crystal microbalance (QCM) sensors. These conductive polymers on admixture with stearyl alcohol were deposited on QCM devices by the Langmuir-Blodgett (LB) technique. These LB films exhibited a selective adsorption for the first-row transitions ions in the Irving-Williams order due to the complexation of metal ions with sulfur atoms in the polymers. These LB film coated QCM sensors were found applicable in detecting heavy metal ions in aqueous solution, which are major pollutants in wastewater. The coated QCM sensors can selectively adsorb heavy metal ions (Hg2+) from solution over a wide range from 0.1 to 100 ppm concentration by complexation with sulfur atoms in the polymers. The bound mercury could be removed by ethylenediaminetetraacetic acid (EDTA) solution. The presence of ferrous, lead, cobalt, and chromium cations in the solution did not interfere with the detection of mercury ions.
引用
收藏
页码:1748 / 1752
页数:5
相关论文
共 26 条
[1]   ELECTROCHEMICAL STUDY OF POLY(3-OCTYLTHIOPHENE) FILM ELECTRODES .1. ELECTROLYTE EFFECTS ON THE VOLTAMMETRIC CHARACTERISTICS OF THE POLYMER - 3 STATES OF THE POLYMER FILM [J].
BOBACKA, J ;
IVASKA, A ;
GRZESZCZUK, M .
SYNTHETIC METALS, 1991, 44 (01) :9-19
[2]  
BORROUGHES JH, 1990, NATURE, V347, P539
[3]   USE OF POLYTHIOPHENE AND POLY(THIOPHENE-3-ACETIC ACID) AS CHARGE-SELECTIVE FILMS FOR AMPEROMETRIC FLOW-CELL DETECTORS [J].
CHAN, HSO ;
TOH, CS ;
GAN, LM .
JOURNAL OF MATERIALS CHEMISTRY, 1995, 5 (04) :631-637
[4]   POLYBITHIOPHENE-MODIFIED ELECTRODE - SPECTROPHOTOMETRIC DETECTION OF ASCORBIC-ACID [J].
CHAN, HSO ;
NG, SC ;
SEOW, SH .
SYNTHETIC METALS, 1994, 66 (02) :177-183
[5]   Metal speciation in biological fluids - A review [J].
Das, AK ;
Chakraborty, R ;
Cervera, ML ;
delaGuardia, M .
MIKROCHIMICA ACTA, 1996, 122 (3-4) :209-246
[6]  
GUILBAULT GG, 1988, CRIT REV ANAL CHEM, V19, P1
[7]  
Hissner F, 1996, FRESEN J ANAL CHEM, V354, P718
[8]   SELECTIVE PIEZOELECTRIC SENSORS USING POLYMER REAGENTS [J].
HUNTER, TC ;
PRICE, GJ .
ANALYST, 1995, 120 (01) :161-165
[9]   Determination of copper, cadmium and lead in biological samples by isotope dilution inductively coupled plasma mass spectrometry after on-line pre-treatment by anodic stripping voltammetry [J].
Hwang, TJ ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (05) :353-357
[10]  
JANE YS, 1995, ANALYST, V120, P5