Assessing the validity of near-infrared monochromator calibrations over time

被引:5
作者
Bouveresse, E [1 ]
Casolino, C [1 ]
Massart, DL [1 ]
机构
[1] Vrije Univ Brussel, Inst Pharmaceut, ChemoAC, B-1090 Brussels, Belgium
关键词
near-infrared spectroscopy; multivariate calibration; instrument standardization; instrument stability; calibration maintenance;
D O I
10.1366/0003702981943941
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A procedure to check the validity of near-infrared calibration models over time is proposed. Validation samples are analyzed at regular time intervals by both near-infrared and reference methods in order to check the validity of the near-infrared calibration model. When an invalid situation is detected, a stable polystyrene standard is measured, to determine whether this invalid situation is due to fluctuations of the instrumental response of the near-infrared spectrometer or not. A first method based on simulating simple instrumental differences enables one to correct those simple differences with only the polystyrene standard. It is shown that such an approach can correct most of the simple instrumental differences without the use of standardization procedures. However, when the invalid situation is due to more complex instrumental differences, standardization must be applied. This procedure is applied to simulated and real near-infrared data sets.
引用
收藏
页码:604 / 612
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 1993, J NEAR INFRARED SPEC, DOI DOI 10.1255/jnirs.25
[2]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[3]   Transfer of near-infrared multivariate calibrations without standards [J].
Blank, TB ;
Sum, ST ;
Brown, SD ;
Monfre, SL .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2987-2995
[4]   Standardisation of near-infrared spectrometric instruments: A review [J].
Bouveresse, E ;
Massart, DL .
VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) :3-15
[5]   CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :405-416
[6]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[7]   Detection, interpretation and correction of changes in the instrumental response of near-infrared monochromator instruments over time [J].
Bouveresse, E ;
Rutan, SC ;
VanderHeyden, Y ;
Penninckx, W ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :283-301
[8]   MODIFIED ALGORITHM FOR STANDARDIZATION OF NEAR-INFRARED SPECTROMETRIC INSTRUMENTS [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1381-1389
[9]   Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration [J].
Bouveresse, E ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) :201-213
[10]   Elimination of uninformative variables for multivariate calibration [J].
Centner, V ;
Massart, DL ;
deNoord, OE ;
deJong, S ;
Vandeginste, BM ;
Sterna, C .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3851-3858