An in vivo method for measuring the mechanical properties of the skin using ultrasound

被引:101
作者
Diridollou, S
Berson, M
Vabre, V
Black, D
Karlsson, B
Auriol, F
Gregoire, JM
Yvon, C
Vaillant, L
Gall, Y
Patat, F
机构
[1] Inst Rech Pierre Fabre, Ctr Jean Louis Alibert Toulouse, F-31405 Toulouse 4, France
[2] CHU Tours, Serv Dermatol, Tours, France
[3] INSERM, U316, Tours, France
[4] GIP Ultrasons, Tours, France
关键词
skin; in vivo; ultrasonic scanning; ultrasound; suction; mechanical; stress; strain;
D O I
10.1016/S0301-5629(97)00237-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this study, we report a new and original device called the "echorheometer," comprising a suction system with an ultrasound scanner (A-mode, TM-mode and B-mode) that enables the simultaneous visualization and measurement of the deformation of skin structures in vivo. With the scanner described here, high resolution is obtained using a strongly focused, wide-band 20-MHz center frequency transducer, with an axial resolution of 0.07 mm. This device can determine, noninvasively, not only those skin structures that are involved in the deformation, but also their morphological variation and their extent of involvement with the degree of stress applied. Using this device, the behavior of the dermis and subcutaneous fat, while under suction, was investigated on the volar forearm of 10 volunteers. The results showed that the resistance to the applied vertical stress is essentially due to the dermis rather than the subcutaneous fat, and that there is a certain amount of infiltration of fluid into the tissues under suction. In addition, it was shown that the dermal response to an applied suction is initially due to its own natural tension and that, with increasing deformation, the intrinsic dermal elasticity has a greater contribution to the resistance of stress. With this information, we hope to develop a mechanical model to define appropriate mechanical parameters for skin. This will allow the evaluation of changes in the dermis and also enable therapeutic intervention to be assessed. Furthermore, it could also be applied to studies of skin ageing and the assessment of cosmetic product efficacy (emolliency, hydratation, etc.). (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 43 条
[1]   MECHANICAL-PROPERTIES AND YOUNGS MODULUS OF HUMAN-SKIN INVIVO [J].
AGACHE, PG ;
MONNEUR, C ;
LEVEQUE, JL ;
DERIGAL, J .
ARCHIVES OF DERMATOLOGICAL RESEARCH, 1980, 269 (03) :221-232
[2]   ACCOUNTING FOR NATURAL TENSION IN MECHANICAL TESTING OF HUMAN-SKIN [J].
ALEXANDER, H ;
COOK, TH .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1977, 69 (03) :310-314
[3]  
Alexander H, 1976, BEDSORE BIOMECHANICS, P109, DOI DOI 10.1007/978-1-349-02492-6_15
[4]  
AURIOL F, 1994, BRIT J DERMATOL, V131, P265
[5]  
AURIOL F, 1993, ACTA DERM-VENEREOL, V73, P344
[6]   INVIVO BIOPHYSICAL CHARACTERIZATION OF SKIN PHYSIOLOGICAL DIFFERENCES IN RACES [J].
BERARDESCA, E ;
DERIGAL, J ;
LEVEQUE, JL ;
MAIBACH, HI .
DERMATOLOGICA, 1991, 182 (02) :89-93
[7]  
Berardesca E., 1986, BIOENG SKIN, V2, P261
[8]   HIGH-RESOLUTION REAL-TIME ULTRASONIC SCANNER [J].
BERSON, M ;
VAILLANT, L ;
PATAT, F ;
POURCELOT, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1992, 18 (05) :471-478
[9]   EFFECTS OF FLUID VOLUME CHANGES DURING HEMODIALYSIS ON THE BIOPHYSICAL PARAMETERS OF THE SKIN [J].
BRAZZELLI, V ;
BORRONI, G ;
VIGNOLI, GP ;
RABBIOSI, G ;
CAVAGNINO, A ;
BERARDESCA, E .
DERMATOLOGY, 1994, 188 (02) :113-116
[10]   EXPERIMENTAL-METHOD FOR DETERMINING 2-DIMENSIONAL MECHANICAL-PROPERTIES OF LIVING HUMAN-SKIN [J].
COOK, T ;
ALEXANDER, H ;
COHEN, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (04) :381-390