Protective ventilation using electrical impedance tomography

被引:77
作者
Luepschen, H.
Meier, T.
Grossherr, M.
Leibecke, T.
Karsten, J.
Leonhardt, S.
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Chair Med Informat Technol, D-52074 Aachen, Germany
[2] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol, D-23538 Lubeck, Germany
[3] Univ Med Ctr Schleswig Holstein, Dept Radiol, D-23538 Lubeck, Germany
关键词
electrical impedance tomography; EIT; automation; protective ventilation; fuzzy controller; recruitment; open lung concept;
D O I
10.1088/0967-3334/28/7/S18
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Dynamic thoracic EIT is capable of detecting changes of the ventilation distribution in the lung. Nevertheless, it has yet to become an established clinical tool. Therefore, it is necessary to consider application scenarios wherein fast and distinct changes of the tissue conductivities are to be found and also have a clear diagnostic significance. One such a scenario is the artificial ventilation of patients suffering from the acute respiratory distress syndrome (ARDS). New protective ventilation strategies involving recruitment manoeuvres are associated with noticeable shifts of body fluids and regional ventilation, which can quite easily be detected by EIT. The bedside assessment of these recruitment manoeuvres will help the attending physician to optimize treatment. Hence, we performed an animal study of lavage-induced lung failure and investigated if EIT is capable of qualitatively as well as quantitatively monitoring lung recruitment during a stepwise PEEP trial. Additionally, we integrated EIT into a fuzzy controller-based ventilation system which allows one to perform automated recruitment manoeuvres (open lung concept) based on online PaO2 measurements. We found that EIT is a useful tool to titrate the proper PEEP level after fully recruiting the lung. Furthermore, EIT seems to be able to determine the status of recruitment when combining it with other physiological parameters. These results suggest that EITmay play an important role in the individualization of protective ventilation strategies.
引用
收藏
页码:S247 / S260
页数:14
相关论文
共 28 条
[1]   Monitoring changes in lung air and liquid volumes with electrical impedance tomography [J].
Adler, A ;
Amyot, R ;
Guardo, R ;
Bates, JHT ;
Berthiaume, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1762-1767
[2]   Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome [J].
Amato, MBP ;
Barbas, CSV ;
Medeiros, DM ;
Magaldi, RB ;
Schettino, GDP ;
Lorenzi, G ;
Kairalla, RA ;
Deheinzelin, D ;
Munoz, C ;
Oliveira, R ;
Takagaki, TY ;
Carvalho, CRR .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (06) :347-354
[3]  
ASHBAUGH DG, 1967, LANCET, V2, P319
[4]   Mechanical ventilation in acute respiratory failure: recruitment and high positive end-expiratory pressure are necessary [J].
Barbas, CSV ;
de Matos, GFJ ;
Pincelli, MP ;
Borges, ED ;
Antunes, T ;
de Barros, JM ;
Okamoto, V ;
Borges, JB ;
Amato, MBP ;
de Carvalho, CRR .
CURRENT OPINION IN CRITICAL CARE, 2005, 11 (01) :18-28
[5]  
Barber D. C., 1986, Inf. Process. Med. Imaging, P106, DOI [10.1007/978-94-009-4261-5_9, DOI 10.1007/978-94-009-4261-5_9]
[6]   Reversibility of lung collapse and hypoxemia in early acute respiratory distress syndrome [J].
Borges, Joao B. ;
Okamoto, Valdelis N. ;
Matos, Gustavo F. J. ;
Caramez, Maria P. R. ;
Arantes, Paula R. ;
Barros, Fabio ;
Souza, Ciro E. ;
Victorino, Josue A. ;
Kacmarek, Robert M. ;
Barbas, Carmen S. V. ;
Carvalho, Carlos R. R. ;
Amato, Marcelo B. P. .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (03) :268-278
[7]  
Borsic A., 2002, THESIS OXFORD BROOKE
[8]   Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. [J].
Brower, RG ;
Matthay, MA ;
Morris, A ;
Schoenfeld, D ;
Thompson, BT ;
Wheeler, A ;
Wiedemann, HP ;
Arroliga, AC ;
Fisher, CJ ;
Komara, JJ ;
Perez-Trepichio, P ;
Parsons, PE ;
Wolkin, R ;
Welsh, C ;
Fulkerson, WJ ;
MacIntyre, N ;
Mallatratt, L ;
Sebastian, M ;
McConnell, R ;
Wilcox, C ;
Govert, J ;
Thompson, D ;
Clemmer, T ;
Davis, R ;
Orme, J ;
Weaver, L ;
Grissom, C ;
Eskelson, M ;
Young, M ;
Gooder, V ;
McBride, K ;
Lawton, C ;
d'Hulst, J ;
Peerless, JR ;
Smith, C ;
Brownlee, J ;
Pluss, W ;
Kallet, R ;
Luce, JM ;
Gottlieb, J ;
Elmer, M ;
Girod, A ;
Park, P ;
Daniel, B ;
Gropper, M ;
Abraham, E ;
Piedalue, F ;
Glodowski, J ;
Lockrem, J ;
McIntyre, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (18) :1301-1308
[9]  
Brown B. H., 2003, Journal of Medical Engineering & Technology, V27, P97, DOI 10.1080/0309190021000059687
[10]   Detection of local lung air content by electrical impedance tomography compared with electron beam CT [J].
Frerichs, I ;
Hinz, J ;
Herrmann, P ;
Weisser, G ;
Hahn, G ;
Dudykevych, T ;
Quintel, M ;
Hellige, G .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (02) :660-666