Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques

被引:131
作者
Nielen, M. W. F.
van Engelen, M. C.
Zuiderent, R.
Ramaker, R.
机构
[1] RIKILT Inst Food Safety, NL-6700 AE Wageningen, Netherlands
[2] Thermo Electron, NL-4801 EB Breda, Netherlands
[3] TNO Qual Life, NL-3700 AJ Zeist, Netherlands
关键词
liquid chromatography mass spectrometry; accurate mass; criteria steroid; residue analysis; Fourier transform mass spectrometry; orbitrap;
D O I
10.1016/j.aca.2006.08.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance (FTICR) or Fourier transform orbitrap (Fr Orbitrap) MS. In this study, mass resolution and accuracy are discussed for LC/MS screening and confirmation of targeted analytes and for the identification of unknowns using the anabolic steroid stanozolol and the designer beta-agonist "Clenbuterol-R" as model substances. It is shown theoretically and experimentally that mass accuracy criteria without proper mass resolution criteria yield false compliant (false negative) results, both in MS screening and MS/MS confirmation of stanozolol. On the other hand, previous medium resolution accurate mass TOFMS/MS data of the designer beta-agonist were fully confirmed by high resolution Fr Orbitrap MS(n) experiments. A discussion is initiated through a proposal for additional criteria for the use of accurate mass LC/MS technologies, to be implemented in Commission Decision 2002/657/EC. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 129
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 2002, OFF J EUR COMMUNITIE
[2]  
BLOKLAND MH, 2005, 2 INT S REC ADV FOOD
[3]   Matrix effects on accurate mass measurements of low-molecular weight compounds using liquid chromatography-electrospray-quadrupole time-of-flight mass spectrometry [J].
Calbiani, F ;
Careri, M ;
Elviri, L ;
Mangia, A ;
Zagnoni, I .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (03) :289-294
[4]   FTMS: Overcoming challenges [J].
Cottingham, K .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :655-657
[5]   Confirmatory analysis of residues of stanozolol and its major metabolite in bovine urine by liquid chromatography-tandem mass spectrometry [J].
Draisci, R ;
Palleschi, L ;
Marchiafava, C ;
Ferretti, E ;
Quadri, FD .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :69-77
[6]   The Orbitrap: a new mass spectrometer [J].
Hu, QZ ;
Noll, RJ ;
Li, HY ;
Makarov, A ;
Hardman, M ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04) :430-443
[7]  
Kostiainen R, 1997, RAPID COMMUN MASS SP, V11, P283
[8]   Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer [J].
Makarov, A ;
Denisov, E ;
Kholomeev, A ;
Baischun, W ;
Lange, O ;
Strupat, K ;
Horning, S .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2113-2120
[9]  
Morris HR, 1996, RAPID COMMUN MASS SP, V10, P889, DOI 10.1002/(SICI)1097-0231(19960610)10:8<889::AID-RCM615>3.0.CO
[10]  
2-F