Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation

被引:84
作者
Brown, Christopher [1 ]
Williams, Sophie [1 ]
Tipper, Joanne L. [1 ]
Fisher, John [1 ]
Ingham, Eileen [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1007/s10856-006-0015-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The failure of metal on polyethylene total hip replacements due to wear particle induced osteolysis and late aseptic loosening has focused interest upon alternative bearings, such as metal on metal implants. A recent advance in this field has been the development of a novel ceramic on metal implant. The characteristics of the wear particles generated in this low-wearing bearing have not been previously determined. The aims of this study were to characterise metal wear particles from metal on metal and ceramic on metal hips under standard and adverse (microseparation) wear conditions. Accurate characterisation of cobalt-chrome wear particles is difficult since the reactive nature of the particles prevents them from being isolated using acids and bases. A method was developed to isolate the metal wear particles using enzymes to digest serum containing lubricants from metal on metal and ceramic on metal hip simulations. High resolution scanning electron microscopy was then used to characterise the wear particles generated by both metal on metal and ceramic on metal implants under standard and microseparation wear conditions. The wear particles isolated from all simulations had a mean size of less than 50 nm with a rounded and irregular morphology. No significant difference was found between the size of wear particles generated under any conditions.
引用
收藏
页码:819 / 827
页数:9
相关论文
共 36 条
[1]
AMSTUTZ HC, 1996, CLIN ORTHOP S, V329, pS297
[2]
A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates [J].
Barbour, PSM ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :455-467
[3]
Subsurface microstructure of metal-on-metal hip joints and its relationship to wear particle generation [J].
Büscher, R ;
Täger, G ;
Dudzinski, W ;
Gleising, B ;
Wimmer, MA ;
Fischer, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (01) :206-214
[4]
WIDESPREAD DISSEMINATION OF METAL DEBRIS FROM IMPLANTS [J].
CASE, CP ;
LANGKAMER, VG ;
JAMES, C ;
PALMER, MR ;
KEMP, AJ ;
HEAP, PF ;
SOLOMON, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05) :701-712
[5]
CASE CP, 1996, CLIN ORTHOP S, V329, P269
[6]
Catelas I, 2001, J BIOMED MATER RES, V55, P330, DOI 10.1002/1097-4636(20010605)55:3<330::AID-JBM1021>3.0.CO
[7]
2-Y
[8]
Catelas I, 2001, J BIOMED MATER RES, V55, P320, DOI 10.1002/1097-4636(20010605)55:3<320::AID-JBM1020>3.0.CO
[9]
2-3
[10]
Increased chromosome translocations and aneuploidy in peripheral blood lymphocytes of patients having revision arthroplasty of the hip [J].
Doherty, AT ;
Howell, RT ;
Ellis, LA ;
Bisbinas, I ;
Learmonth, ID ;
Newson, R ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (07) :1075-1081