Development and testing of image-processing methods for the quantitative assessment of airway hyperresponsiveness from high-resolution CT images

被引:64
作者
McNittGray, MF
Goldin, JG
Johnson, TD
Tashkin, DP
Aberle, DR
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, DEPT BIOSTAT, LOS ANGELES, CA 90095 USA
[2] UNIV CALIF LOS ANGELES, SCH MED, DEPT INTERNAL MED, DIV PULM & CRIT CARE MED, LOS ANGELES, CA 90095 USA
关键词
image processing; image analysis; computed tomography; physics and instrumentation; asthma; bronchi; diseases; bronchospasm; computer workstations;
D O I
10.1097/00004728-199711000-00017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal was to develop a protocol and image-processing methods to quantitate both bronchial and lung attenuation changes in patients imaged with helical high-resolution CT (HRCT). Method: Human subjects underwent helical HRCT at two suspended breath-hold conditions, functional residual capacity and residual volume, at baseline and following methacholine-induced bronchoprovocation. A semiautomated contouring program was used to define anatomically like bronchi and axial lung sections from the different physiologic sequences, from which automated measurements of area, shape, and attenuation were made. Because the gray level threshold for contouring directly affects the measured area of an anatomic structure, two types of evaluation studies were performed. These included in vivo measurements using baseline parameters of human subjects as the standard of reference and in vitro measurements of a CT phantom designed to simulate the air-soft tissue interfaces of bronchi. Results: Phantom tests showed that the minimum difference between actual and measured areas of holes occurred at a threshold of -500 HU. The smallest diameter holes were most sensitive to changes in threshold value. However, although absolute area measurements of both simulated and human bronchi varied with threshold level, the percent changes in airway areas between baseline and bronchoprovocation sequences were relatively stable at any given threshold. Conclusion: These image-processing tools provide reproducible measurements of area as well as attenuation characteristics of pulmonary structures and may offer insights into the practical use of functional imaging in evaluating conditions of airflow obstruction.
引用
收藏
页码:939 / 947
页数:9
相关论文
共 30 条
[11]   MEASUREMENT OF PULMONARY PARENCHYMAL ATTENUATION - USE OF SPIROMETRIC GATING WITH QUANTITATIVE CT [J].
KALENDER, WA ;
RIENMULLER, R ;
SEISSLER, W ;
BEHR, J ;
WELKE, M ;
FICHTE, H .
RADIOLOGY, 1990, 175 (01) :265-268
[12]   QUANTITATION OF EMPHYSEMA BY COMPUTED-TOMOGRAPHY USING A DENSITY MASK PROGRAM AND CORRELATION WITH PULMONARY-FUNCTION TESTS [J].
KINSELLA, M ;
MULLER, NL ;
ABBOUD, RT ;
MORRISON, NJ ;
DYBUNCIO, A .
CHEST, 1990, 97 (02) :315-321
[13]   NONSPECIFICITY OF BRONCHOCONSTRICTING EFFECT OF HISTAMINE AND ACETYL-BETA-METHYLCHOLINE IN PATIENTS WITH OBSTRUCTIVE AIRWAY DISEASE [J].
KLEIN, RC ;
SALVAGGIO, JE .
JOURNAL OF ALLERGY, 1966, 37 (03) :158-+
[14]  
LOUIS O, 1988, EUR J RADIOL, V8, P82
[15]   ASTHMA [J].
MCFADDEN, ER ;
GILBERT, IA .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (27) :1928-1937
[16]   AIRWAY NARROWING IN EXCISED CANINE LUNGS MEASURED BY HIGH-RESOLUTION COMPUTED-TOMOGRAPHY [J].
MCNAMARA, AE ;
MULLER, NL ;
OKAZAWA, M ;
ARNTORP, J ;
WIGGS, BR ;
PARE, PD .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (01) :307-316
[17]  
MCNITTGRAY MF, 1994, RADIOLOGY, V193, P470
[18]  
MCNITTGRAY MF, 1994, MED PHYS, V21, P905
[19]   Classification of Atrial Fibrillation and Acute Decompensated Heart Failure Using Smartphone Mechanocardiography: A Multilabel Learning Approach [J].
Mehrang, Saeed ;
Lahdenoja, Olli ;
Kaisti, Matti ;
Tadi, Mojtaba Jafari ;
Hurnanen, Tero ;
Airola, Antti ;
Knuutila, Timo ;
Jaakkola, Jussi ;
Jaakkola, Samuli ;
Vasankari, Tuija ;
Kiviniemi, Tuomas ;
Airaksinen, Juhani ;
Koivisto, Tero ;
Pankaala, Mikko .
IEEE SENSORS JOURNAL, 2020, 20 (14) :7957-7968
[20]   DENSITY MASK - AN OBJECTIVE METHOD TO QUANTITATE EMPHYSEMA USING COMPUTED-TOMOGRAPHY [J].
MULLER, NL ;
STAPLES, CA ;
MILLER, RR ;
ABBOUD, RT .
CHEST, 1988, 94 (04) :782-787