Corneal surface topography and associated visual performance with INTACS for myopia - Phase III clinical trial results

被引:30
作者
Holmes-Higgin, DK [1 ]
Burris, TE [1 ]
机构
[1] NW corneal Serv, Corneal Topog Res Ctr, Portland, OR 97223 USA
关键词
D O I
10.1016/S0161-6420(00)00374-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To characterize corneal topography with INTACS (KeraVision, Inc., Fremont, CA) an ophthalmic device designed to correct myopia, and relate findings to visual performance. Design: Prospective nonrandomized self-controlled comparative intervention study. Participants/Intervention: Patients were participants in the INTACS FDA phase III clinical trials. Main outcome Measures: Preoperative and postoperative month 6 videokeratographic corneal topography (EyeSys, Houston, TX) was analyzed for 165 eyes from eight clinical sites. Topographic flattening, asphericity, and surface characteristics were statistically evaluated for relationship to visual acuity, refractive data, contrast sensitivity, and subjective visual symptoms. Results: Corneal radius of curvature flattening was aspheric in nature and increased incrementally and significantly for progressively thicker INTACS (P < 0.05), Comparative stratification analyses suggest potential interactions between existing preoperative asphericity and myopia, postoperative asphericity, and visual performance outcomes. Qualitative symmetric and asymmetric toric topography patterns were related to the postoperative self-reported visual symptoms of "double images" (P <less than or equal to> 0.05) and "halos" (P less than or equal to 0.10), respectively. Conclusions: The anterior corneal surface is aspherically flattened (prolately) with INTACS, whereas postoperative corneal asphericity is significantly more prolate than preoperative. Specific qualitative postoperative topography patterns were associated with subjective clinical visual performance. Ophthalmology 2000,107.2061-2071 (C) 2000 by the American Academy of Ophthalmology.
引用
收藏
页码:2061 / +
页数:12
相关论文
共 52 条
[41]   The intrastromal corneal ring segments - Phase II results for the correction of myopia [J].
Schanzlin, DJ ;
Asbell, PA ;
Burris, TE ;
Durrie, DS .
OPHTHALMOLOGY, 1997, 104 (07) :1067-1078
[42]   Optical modeling of radial keratotomy incision patterns [J].
Schwiegerling, J ;
Greivenkamp, JE ;
Miller, JM ;
Snyder, RW ;
Palmer, ML .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (06) :808-817
[43]  
Seiler T, 1993, Refract Corneal Surg, V9, P166
[44]   THE SPHERICAL-ABERRATION OF INTRA-OCULAR LENSES [J].
SMITH, G ;
LU, CW .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (03) :287-294
[45]  
SMITH G, 1997, EYE VISUAL OPTICAL I, V97, P673
[46]  
TOWNSLEY GM, 1970, CONTACTO, V14, P38
[47]  
Twa M D, 1999, J Am Optom Assoc, V70, P515
[48]  
Waring G O 3rd, 1989, Refract Corneal Surg, V5, P362
[49]  
WARING GO, 1992, CORNEAL TOPOGRAPHY M, P47
[50]  
WILSON SE, 1994, OPHTHALMOLOGY, V101, P147