Simultaneous electrochemical determination of xanthine and uric acid at a nanoparticle film electrode

被引:78
作者
Sun, YY [1 ]
Fei, JJ [1 ]
Wu, KB [1 ]
Hu, SS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-wall carbon nanotubes; uric acid; xanthine; modified glassy carbon electrode; voltammetry;
D O I
10.1007/s00216-002-1743-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive electrochemical method was developed for simultaneous determination of uric acid (UA) and xanthine (XA) at a glassy carbon electrode modified with multi-wall carbon nanotubcs (MWNTs) film. The oxidation peak currents of UA and XA were increased at the MWNTs film electrode significantly. The experimental parameters, which influence the peak currents of UA and XA, such as the amount of MWNTs on the glassy carbon electrode, the pH of the solution, accumulation time, and scan rate, were optimized. Under optimum conditions, the peak currents were linear to the concentration of UA over the wide range from 1x10(-7) mol L-1 to 1x10(-4) mol L-1 and to that of XA over the wide range from 2x10(-8) mol L-1 to 2x10(-5) mol L-1. The interferences studies showed that the MWNTs-modified electrode exhibited excellent selectivity in the presence of ascorbic acid, dopamine, and hypoxanthine. The proposed procedure was successfully applied to detect UA and XA in human serum without any preliminary treatment.
引用
收藏
页码:544 / 549
页数:6
相关论文
共 35 条
[1]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[2]   Carbon nanotube actuators [J].
Baughman, RH ;
Cui, CX ;
Zakhidov, AA ;
Iqbal, Z ;
Barisci, JN ;
Spinks, GM ;
Wallace, GG ;
Mazzoldi, A ;
De Rossi, D ;
Rinzler, AG ;
Jaschinski, O ;
Roth, S ;
Kertesz, M .
SCIENCE, 1999, 284 (5418) :1340-1344
[3]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[4]  
Britto PJ, 1999, ADV MATER, V11, P154, DOI 10.1002/(SICI)1521-4095(199902)11:2<154::AID-ADMA154>3.0.CO
[5]  
2-B
[6]   SIMULTANEOUS DETERMINATION OF URIC-ACID, XANTHINE AND HYPOXANTHINE WITH AN ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODE [J].
CAI, X ;
KALCHER, K ;
NEUHOLD, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (10) :660-665
[7]   Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination [J].
Carsol, MA ;
Volpe, G ;
Mascini, M .
TALANTA, 1997, 44 (11) :2151-2159
[8]   Carbon nanotubule membranes for electrochemical energy storage and production [J].
Che, GL ;
Lakshmi, BB ;
Fisher, ER ;
Martin, CR .
NATURE, 1998, 393 (6683) :346-349
[9]   High H2 uptake by alkali-doped carbon nanotubes under ambient pressure and moderate temperatures [J].
Chen, P ;
Wu, X ;
Lin, J ;
Tan, KL .
SCIENCE, 1999, 285 (5424) :91-93
[10]   Nanotubes as nanoprobes in scanning probe microscopy [J].
Dai, HJ ;
Hafner, JH ;
Rinzler, AG ;
Colbert, DT ;
Smalley, RE .
NATURE, 1996, 384 (6605) :147-150