The role of macular pigment assessment in clinical practice: a review

被引:27
作者
Bartlett, Hannah [1 ]
Howells, Olivia [1 ]
Eperjesi, Frank [1 ]
机构
[1] Aston Univ, Ophthalm Res Grp, Sch Life & Hlth Sci, Birmingham, W Midlands, England
关键词
heterochromatic flicker photometry; lutein; macular pigment; macular pigment optical density; zeaxanthin; HETEROCHROMATIC FLICKER PHOTOMETRY; AGE-RELATED MACULOPATHY; OPTICAL-DENSITY; HUMAN RETINA; LUTEIN SUPPLEMENTATION; EYE DISEASE; SERUM CONCENTRATIONS; RAMAN-SPECTROSCOPY; PRIMATE RETINAS; SPATIAL PROFILE;
D O I
10.1111/j.1444-0938.2010.00499.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso-zeaxanthin on macular pigment optical density measurement techniques published in peer-reviewed journals, through a multi-staged, systematic approach. Twenty-four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naive subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20 mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20 mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.
引用
收藏
页码:300 / 308
页数:9
相关论文
共 76 条
[1]  
Aleman TS, 2001, INVEST OPHTH VIS SCI, V42, P1873
[2]   Clinical evaluation of the MPS 9000 Macular Pigment Screener [J].
Bartlett, Hannah ;
Stainer, Louise ;
Singh, Sandip ;
Eperjesi, Frank ;
Howells, Olivia .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (06) :753-756
[3]   Clinical evaluation of the MacuScope macular pigment densitometer [J].
Bartlett, Hannah ;
Acton, Jennifer ;
Eperjesi, Frank .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (03) :328-331
[4]  
Beatty S, 2000, OPHTHAL PHYSL OPT, V20, P105, DOI 10.1016/S0275-5408(99)00039-3
[5]  
Beatty S, 2001, INVEST OPHTH VIS SCI, V42, P439
[6]   Resonance Raman measurement of macular carotenoids in the living human eye [J].
Bernstein, PS ;
Zhao, DY ;
Sharifzadeh, M ;
Ermakov, IV ;
Gellermann, W .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2004, 430 (02) :163-169
[7]   HPLC measurement of ocular carotenoid levels in human donor eyes in the lutein supplementation era [J].
Bhosale, Prakash ;
Zhao, Da You ;
Bernstein, Paul S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (02) :543-549
[8]   Retinal carotenoids can attenuate formation of A2E in the retinal pigment epithelium [J].
Bhosale, Prakash ;
Serban, Bogdan ;
Bernstein, Paul S. .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 2009, 483 (02) :175-181
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]   Distribution of lutein and zeaxanthin stereoisomers in the human retina [J].
Bone, RA ;
Landrum, JT ;
Friedes, LM ;
Gomez, CM ;
Kilburn, MD ;
Menendez, E ;
Vidal, I ;
Wang, WL .
EXPERIMENTAL EYE RESEARCH, 1997, 64 (02) :211-218