On-line bidirectional electrostacking of chromium(III) and chromium(VI) for flame atomic absorption spectrometry determination

被引:24
作者
He, YZ [1 ]
Cervera, ML [1 ]
Garrido-Ecija, MI [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
关键词
bidirectional electrostacking; flow injection; Cr(III); Cr(VI); flame atomic absorption spectrometry;
D O I
10.1016/S0003-2670(00)01027-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line bidirectional electrostacking-flow injection-flame atomic absorption spectrometry method has been developed for the simultaneous separation, pre-concentration and determination of Cr(III) and Cr(VI). The electrostacking-flow injection unit was established, the pH and components of the support buffer and sample medium were investigated. Results indicated that the ionic mobility, electric field strength and sample area cross-section are the main influence factors on the electrostacking. The calibration range for both, Cr(III) and Cr(VI), was from 20 to 400 mu g l(-1). The limit of detection was 7 mu g l(-1) for three-times the standard deviation of blank values using a electrostacking time of 350 s. The recovery percentages of 100 mu g l(-1) Cr(III) and 25 mu g l(-1) Cr(VI) added to samples were 100 and 94% with variation coefficients of 7 and 10%, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 22 条
[1]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[2]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[3]   FIELD AMPLIFIED SAMPLE INJECTION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
CHIEN, RL ;
BURGI, DS .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :141-152
[4]   ELECTROOSMOSIS - A RELIABLE FLUID PROPULSION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
DASGUPTA, PK ;
LIU, S .
ANALYTICAL CHEMISTRY, 1994, 66 (11) :1792-1798
[5]   DETERMINATION OF SUBSTANCES AT LOW CONCENTRATIONS IN COMPLEX-MIXTURES BY ISOTACHOPHORESIS WITH COLUMN COUPLING [J].
EVERAERTS, FM ;
VERHEGGEN, TPEM ;
MIKKERS, FEP .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :21-38
[6]  
EWING A G, 1989, Analytical Chemistry, V61, P292
[7]  
Foret F, 1990, J MICROCOLUMN SEP, V2, P229
[8]   Improvement on simultaneous determination of chromium species in aqueous solution by ion chromatography and chemiluminescence detection [J].
Gammelgaard, B ;
Liao, YP ;
Jons, O .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :107-113
[9]   Mechanism of porous core electroosmotic pump flow injection system and its application to determination of chromium(VI) in waste-water [J].
Gan, WE ;
Yang, L ;
He, YZ ;
Zeng, RH ;
Cervera, ML ;
de la Guardia, M .
TALANTA, 2000, 51 (04) :667-675
[10]  
GUO ZX, 1997, FENXI SHIYANSHI, V16, P14