Sirolimus- and paclitaxel-eluting stents in comparison with balloon angioplasty for treatment of in-stent restenosis

被引:30
作者
Iofina, E [1 ]
Haager, PK [1 ]
Radke, PW [1 ]
Langenberg, R [1 ]
Blindt, R [1 ]
Ortlepp, J [1 ]
Kühl, H [1 ]
Hanrath, P [1 ]
Hoffmann, R [1 ]
机构
[1] Univ RWTH Aachen, Med Clin 1, D-52057 Aachen, Germany
关键词
angioplasty; drugs; restenosis; stents;
D O I
10.1002/ccd.20212
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the acute and follow-up effectiveness of sirolimus-eluting stents (SESs) and nonpolymer-based paclitaxel-eluting stents (PESs) in comparison will balloon angioplasty for treatment of complex in-stent restenosis (ISR) lesions. Drug-eluting stents have been demonstrated to be highly effective for treatment of de novo lesions. The use of drug-eluting stents for treatment of complex ISR is less well defined. Eighty one lesions with in-stent restenosis (lesion length < 30 mm in a native coronary artery) were treated with either PTCA alone (n = 26 lesions in 25 patients), PES (n = 27 lesions in 24 patients; Achieve, Cook; 3,1 mug paclitaxel/mm(2) nonpolymer-based coating), SES (n = 28 lesions in 28 patients; Cypher, Cordis; 140 mug sirolimus/cm(2) metal surface area). Nine-month MACE rates were 32%, 8%, and 14% (all due to repeated revascularization procedures, except one death in the SES group) in the PTCA, PES, and SES group, respectively. Postintervention minimal lumen diameter in stent was significantly greater in the SES and the PES group in comparison with the PTCA group (2.37 +/- 0.26, 2.54 +/- 0.42, 1.78 +/- 0.23 mm; P<0.001). At 6-month angiographic follow-up, late loss in stent was 0.77 +/- 0.45, 0.43 +/- 0.53, and 0.29 +/- 0.52 mm for the PTCA, PES, and SES group, respectively (P = 0.005). In-lesion restenosis rate was 61% for the PTCA group, 20% for the PES group, and 13% for the SES group (P = 0.042). The implantation of SES as well as nonpolymer PES proved to be effective for treatment of ISR. The combination of improved acute gain and reduced late loss results in a significantly improved angiographic follow-up result in comparison with PTCA. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 24 条
  • [1] Cutting balloon angioplasty for the treatment of in-stent restenosis: A matched comparison with rotational atherectomy, additional stent implantation and balloon angioplasty
    Adamian, M
    Colombo, A
    Briguori, C
    Nishida, T
    Marsico, F
    Di Mario, C
    Albiero, R
    Moussa, I
    Moses, JW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) : 672 - 679
  • [2] Edge restenosis after implantation of high activity 32P radioactive β-emitting stents
    Albiero, R
    Nishida, T
    Adamian, M
    Amato, A
    Vaghetti, M
    Corvaja, N
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2000, 101 (21) : 2454 - 2457
  • [3] A randomized comparison of repeat stenting with balloon angioplasty in patients with in-stent restenosis
    Alfonso, F
    Zueco, J
    Cequier, A
    Mantilla, R
    Bethencourt, A
    López-Minguez, JR
    Angel, J
    Augé, JM
    Gómez-Recio, M
    Morís, C
    Seabra-Gomes, R
    Perez-Vizcayno, MJ
    Macaya, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (05) : 796 - 805
  • [4] Late coronary occlusion after intracoronary brachytherapy
    Costa, MA
    Sabaté, M
    van der Giessen, WJ
    Kay, IP
    Cervinka, P
    Ligthart, JMR
    Serrano, P
    Coen, VLMA
    Levendag, PC
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (08) : 789 - 792
  • [5] Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis
    Dauerman, HL
    Baim, DS
    Cutlip, D
    Sparano, AM
    Gibson, CM
    Kuntz, RE
    Carrozza, JP
    Garber, GR
    Cohen, DJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) : 277 - 284
  • [6] Sirolimus-eluting stent for treatment of complex in-stent restenosis - The first clinical experience
    Degertekin, M
    Regar, E
    Tanabe, K
    Smits, PC
    van der Giessen, WJ
    Carlier, SG
    de Feyter, P
    Vos, J
    Foley, DP
    Ligthart, JMR
    Popma, JJ
    Serruys, PW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (02) : 184 - 189
  • [7] Inhibition of restenosis with a paclitaxel-eluting, polymer-free coronary stent - The European evaLUation of pacliTaxel Eluting Stent (ELUTES) trial
    Gershlick, A
    De Scheerder, I
    Chevalier, B
    Stephens-Lloyd, A
    Camenzind, E
    Vrints, C
    Reifart, N
    Missault, L
    Goy, JJ
    Brinker, JA
    Raizner, AE
    Urban, P
    Heldman, AW
    [J]. CIRCULATION, 2004, 109 (04) : 487 - 493
  • [8] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [9] Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting.
    Leon, MB
    Teirstein, PS
    Moses, JW
    Tripuraneni, P
    Lansky, AJ
    Jani, S
    Wong, SC
    Fish, D
    Ellis, S
    Holmes, DR
    Kerieakes, D
    Kuntz, RE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (04) : 250 - 256
  • [10] Coronary in-stent restenosis: Current status and future strategies
    Lowe, HC