Carotid endarterectomy: The mandate for high quality duplex

被引:23
作者
Elmore, JR [1 ]
Franklin, DP [1 ]
Thomas, DD [1 ]
Youkey, JR [1 ]
机构
[1] Geisinger Med Ctr, Vasc Surg Sect, Danville, PA 17822 USA
关键词
D O I
10.1007/s100169900134
中图分类号
R61 [外科手术学];
学科分类号
摘要
Excellent correlation between carotid angiography and duplex scanning has made it possible to perform carotid endarterectomy without angiography. The accuracy of scans from practices without a dedicated vascular laboratory must be validated prior to their use for clinical decisions. Seventy six patients had a carotid duplex performed at an outside institution and were referred for vascular surgery. All patients underwent a repeat study at our dedicated vascular lab. The overall accuracy of our lab was 93.8% for all carotid categories as demonstrated by angiography. Outside carotid duplex reports correlated with repeat exams as follows: occlusions: 10/13 carotids (76.9%); 80%-99% stenoses: 15/39 carotids (38.5%); 50%-79% stenoses: 28/44 carotids (63.6%). If a surgeon's practice is to operate for asymptomatic 80%-99% stenoses by report, then unnecessary surgery might have been performed in 61.5% of these carotids and appropriate surgery denied in 3.6%. Outside duplex velocities consistent with a 60%-99% stenosis correlated in 13/17 carotids (76.5%). If a surgeon's practice is to operate for asymptomatic 60%-99% stenoses based on velocity criteria, then unnecessary surgery might have been performed in 23.5% of these carotids, and appropriate surgery denied in 7.6% placing these patients al increased risk of stroke. Outside scans significantly overestimated the severity of carotid disease (p = 0.003). The weighted kappa analysis for agreement between scans was only 60.2%. Failure to have validated high-quality duplex in labs performing carotid studies can lead to unnecessary angiography or surgery. Carotid endarterectomy without angiography should be performed only when duplex accuracy has been previously validated by angiographic correlation studies. Poor agreement with studies from practices without a dedicated vascular lab makes it mandatory to repeat the duplex on all patients prior to clinical decision making. Reimbursement for such repeat studies should not be denied.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 12 条
[1]  
ALEXANDROV AV, 1996, J VASC TECH, V20, P205
[2]   THE DIAGNOSTIC-ACCURACY OF DUPLEX ULTRASONOGRAPHY FOR EVALUATING CAROTID BIFURCATION [J].
BALLARD, JL ;
FLEIG, K ;
DELANGE, M ;
KILLEEN, JD .
AMERICAN JOURNAL OF SURGERY, 1994, 168 (02) :123-126
[3]  
GELABERT HA, 1990, SURG CLIN N AM, V70, P213
[4]  
Gertler J P, 1991, Ann Vasc Surg, V5, P253, DOI 10.1007/BF02329382
[5]   EPIDEMIOLOGY OF CAROTID ENDARTERECTOMY AND CEREBRAL ARTERIOGRAPHY IN THE UNITED-STATES [J].
GILLUM, RF .
STROKE, 1995, 26 (09) :1724-1728
[6]  
Howard G, 1991, J Stroke Cerebrovasc Dis, V1, P166, DOI 10.1016/S1052-3057(10)80013-8
[7]   SCREENING FOR ASYMPTOMATIC INTERNAL CAROTID-ARTERY STENOSIS - DUPLEX CRITERIA FOR DISCRIMINATING 60-PERCENT TO 99-PERCENT STENOSIS [J].
MONETA, GL ;
EDWARDS, JM ;
PAPANICOLAOU, G ;
HATSUKAMI, T ;
TAYLOR, LM ;
STRANDNESS, DE ;
PORTER, JM .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (06) :989-994
[8]  
RANGER WR, 1995, AM SURGEON, V61, P548
[9]  
ROEDERER GO, 1984, BRUIT, V8, P174
[10]  
TAYLOR DW, 1991, NEW ENGL J MED, V325, P445