Kneeling kinematics after total knee arthroplasty: anterior-posterior contact position of a standard and a high-flex tibial insert design

被引:45
作者
Coughlin, Kathryn M.
Incavo, Stephen J. [1 ]
Doohen, Robert R.
Gamada, Kazuyoshi
Banks, Scott
Beynnon, Bruce D.
机构
[1] Univ Vermont, Coll Med, Dept Orthopaed & Rehabil, Mcclure Musculoskeletal Res Ctr, Burlington, VT 05405 USA
[2] Univ Florida, Orthopaed Biomech Lab, Gainesville, FL USA
关键词
kneeling; deep flexion; kinematics; in vivo; total knee arthroplasty;
D O I
10.1016/j.arth.2006.05.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Deep flexion activities including kneeling are desired by patients after total knee arthroplasty. This in vivo radiographic study sought to reveal the effect of tibial insert design on tibiofemoral kinematics during kneeling. One group of patients received standard posterior stabilized tibial inserts, whereas the other group received posterior stabilized tibial inserts (Flex inserts) that were designed to allow more flexion. The patients with the Flex inserts achieved greater range of motion without different tibiofemoral contact behavior.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 18 条
[1]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[2]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]
Mechanism of anterior impingement damage in total knee arthroplasty [J].
Banks, SA ;
Harman, MK ;
Hodge, WA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A :37-42
[4]
Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset [J].
Bellemans, J ;
Banks, S ;
Victor, J ;
Vandenneucker, H ;
Moemans, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B :50-53
[5]
Tibial post impingement in posterior-stabilized total knee arthroplasty [J].
Callaghan, JJ ;
O'Rourke, MR ;
Goetz, DA ;
Schmalzried, TP ;
Campbell, PA ;
Johnston, RC .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :83-88
[6]
Femoral condylar lift-off in vivo in total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Walker, SA ;
Cheal, EJ ;
Stiehl, JB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :33-39
[7]
Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752
[8]
DENNIS DA, 1998, CLIN ORTHOP RELAT R, V356, P47
[9]
Tibiofemoral kinematic analysis of kneeling after total knee arthroplasty [J].
Incavo, SJ ;
Mullins, ER ;
Coughlin, KM ;
Banks, S ;
Banks, A ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2004, 19 (07) :906-910
[10]
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13