Preparation of non-thrombogenic materials using 2-methacryloyloxyethyl phosphorylcholine

被引:124
作者
Nakabayashi, N
Williams, DF
机构
[1] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Div Organ Mat, Chiyoda Ku, Tokyo 1010062, Japan
[2] Univ Liverpool, Dept Clin Engn, Liverpool, Merseyside, England
关键词
phosphorylcholine; membrane; blood compatibility;
D O I
10.1016/S0142-9612(03)00113-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This review addresses the non-thrombogenic characteristics of copolymers based on 2-methacryloyloxyethyl phosphorylcholine (MPC), originally developed by Nakabayashi and colleagues. The hypothesis underlying these developments was that such materials would adsorb phospholipids from blood, yielding surfaces with good natural blood compatibility. Methacrylates were found to have excellent properties for this copolymerisation. The characteristics of the MPC copolymers relevant to the improved blood compatibility were minimisation of protein adsorption through an increase in the amount of free water in the MPC hydrogels, which prevents protein conformational change and increased protein stability in solution. Non-thrombogenicity has been evaluated by in vitro, ex vivo and in vivo procedures. Non-thrombogenic dialysis membranes and a durable glucose biosensor have been developed using this MPC copolymer. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2431 / 2435
页数:5
相关论文
共 27 条
[1]   Improving the blood compatibility of ion-selective electrodes by employing poly(MPC-co-BMA), a copolymer containing phosphorylcholine, as a membrane coating [J].
Berrocal, MJ ;
Johnson, RD ;
Badr, IHA ;
Liu, MD ;
Gao, DY ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3644-3648
[2]   Phosphorylcholine coating of ePTFE grafts reduces neointimal hyperplasia in canine model [J].
Chen, CY ;
Lumsden, AB ;
Ofenloch, JC ;
Noe, B ;
Campbell, EJ ;
Stratford, PW ;
Yianni, YP ;
Taylor, AS ;
Hanson, SR .
ANNALS OF VASCULAR SURGERY, 1997, 11 (01) :74-79
[3]   Preparation of blood-compatible hollow fibers from a polymer alloy composed of polysulfone and 2-methacryloyloxyethyl phosphorylcholine polymer [J].
Hasegawa, T ;
Iwasaki, Y ;
Ishihara, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (03) :333-341
[4]   BIOMEMBRANE SURFACES AS MODELS FOR POLYMER DESIGN - THE POTENTIAL FOR HEMOCOMPATIBILITY [J].
HAYWARD, JA ;
CHAPMAN, D .
BIOMATERIALS, 1984, 5 (03) :135-142
[5]  
Ishihara K, 1998, J BIOMED MATER RES, V39, P323, DOI 10.1002/(SICI)1097-4636(199802)39:2<323::AID-JBM21>3.0.CO
[6]  
2-C
[7]  
Ishihara K., 1994, Japanese Journal of Artificial Organs, V23, P654
[8]   HEMOCOMPATIBILITY OF HUMAN WHOLE-BLOOD ON POLYMERS WITH A PHOSPHOLIPID POLAR GROUP AND ITS MECHANISM [J].
ISHIHARA, K ;
OSHIDA, H ;
ENDO, Y ;
UEDA, T ;
WATANABE, A ;
NAKABAYASHI, N .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (12) :1543-1552
[9]   IMPROVEMENT OF HEMOCOMPATIBILITY ON A CELLULOSE DIALYSIS MEMBRANE WITH A NOVEL BIOMEDICAL POLYMER HAVING A PHOSPHOLIPID POLAR GROUP [J].
ISHIHARA, K ;
FUKUMOTO, K ;
MIYAZAKI, H ;
NAKABAYASHI, N .
ARTIFICIAL ORGANS, 1994, 18 (08) :559-564
[10]   PREPARATION OF PHOSPHOLIPID POLYMERS AND THEIR PROPERTIES AS POLYMER HYDROGEL MEMBRANES [J].
ISHIHARA, K ;
UEDA, T ;
NAKABAYASHI, N .
POLYMER JOURNAL, 1990, 22 (05) :355-360