摘要
This paper reviews the technological developments in neural orthoses for the correction of upper motor neurone drop foot since 1961, when the technique was first proposed by Liberson and his co-workers. Drop foot stimulator (DFS) developments are reviewed starting with hard-wired single-channel and multichannel surface functional electrical stimulation (FES) systems, followed by implanted drop foot stimulators, and then continuing with microprocessor-based surface and implanted drop foot stimulators. The review examines the role of artificial and "natural" sensors as replacements for the foot-switch as the primary control sensor in drop foot stimulators. DFS systems incorporating real-time control of FES and completely implanted DFS systems finish the review.
引用
收藏
页码:260 / 279
页数:20
相关论文
共 67 条
[1]  
ACIMOVIC R, 1987, P 10 RESNA C, P621
[2]   RESTORATION OF GAIT DURING 2 TO 3 WEEKS OF THERAPY WITH MULTICHANNEL ELECTRICAL-STIMULATION [J].
BOGATAJ, U ;
GROS, N ;
MALEZIC, M ;
KELIH, B ;
KLJAJIC, M ;
ACIMOVIC, R .
PHYSICAL THERAPY, 1989, 69 (05) :319-327
[3]  
Bogataj U., 1984, P 2 INT C REH ENG, P529
[4]   EFFECTS OF WAVEFORM PARAMETERS ON COMFORT DURING TRANS-CUTANEOUS NEUROMUSCULAR ELECTRICAL-STIMULATION [J].
BOWMAN, BR ;
BAKER, LL .
ANNALS OF BIOMEDICAL ENGINEERING, 1985, 13 (01) :59-74
[5]  
BOWMAN BR, 1984, P 8 INT S EXT CONTR, P429
[6]  
BRANDELL BR, 1982, AM J PHYS MED REHAB, V61, P279
[7]   Experience of clinical use of the Odstock dropped foot stimulator [J].
Burridge, J ;
Taylor, P ;
Hagan, S ;
Swain, I .
ARTIFICIAL ORGANS, 1997, 21 (03) :254-260
[8]  
Burridge JH, 1997, P 5 IPEM CLIN FUNCT, P8
[9]   SENSORS FOR USE WITH FUNCTIONAL NEUROMUSCULAR STIMULATION [J].
CRAGO, PE ;
CHIZECK, HJ ;
NEUMAN, MR ;
HAMBRECHT, FT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :256-268
[10]  
Creasey G. H., 2000, P 6 TRIENN NEUR PROS, P517