Antibody functionalized interdigitated μ-electrode (IDμE) based impedimetric cortisol biosensor

被引:63
作者
Arya, Sunil K. [1 ]
Chornokur, Ganna [1 ]
Venugopal, Manju [2 ]
Bhansali, Shekhar [1 ]
机构
[1] Univ S Florida, BioMEMS & Microsyst Lab, Dept Elect Engn, Tampa, FL 33620 USA
[2] Guided Therapeut Inc, Norcross, GA 30092 USA
关键词
LABEL-FREE; IMPEDANCE SPECTROSCOPY; ENZYME-IMMUNOASSAY; DNA; IMMUNOSENSOR; RADIOIMMUNOASSAY; ULTRAFILTRATION; CHROMATOGRAPHY; TECHNOLOGY; SURFACES;
D O I
10.1039/c0an00242a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on an ultrasensitive, disposable, impedimetric biosensor for cortisol detection. C-Mab (a Cortisol specific monoclonal antibody) was covalently immobilized via amide bond on the surface of the interdigitated mu-electrodes (ID mu Es) functionalized with dithiobis(succinimidyl propionate) (DTSP) self-assembled monolayer (SAM). After C-Mab binding, unreacted active groups of DTSP were blocked using ethanolamine (EA) and glycine (Gly) mixture. The disposable sensors were exposed to solutions with different cortisol concentrations and a label-free electrochemical impedance (EIS) technique was used to determine the cortisol concentration. EIS results confirm that the EA-Gly/C-Mab/DTSP/ID mu E based biosensor exhibited the sensitivity of 2.855 kohms M-1 and could accurately detect cortisol in the range of 1 pM to 10 nM in saliva. This work establishes the feasibility of using an impedance based biosensor as a disposable cortisol detector, capable of working with complex bodily fluids (e.g., saliva). The architecture enables the use of cortisol sensors at point-of-care.
引用
收藏
页码:1941 / 1946
页数:6
相关论文
共 48 条
[1]  
ALEGRET S, 2003, INTEGRATED ANAL SYST, V39, pCH1
[2]   A fluorimetric assay for cortisol [J].
Appel, D ;
Schmid, RD ;
Dragan, CA ;
Bureik, M ;
Urlacher, VB .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) :182-186
[3]   Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor [J].
Arya, Sunil K. ;
Pandey, Pratibha ;
Singh, Surinder P. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYST, 2007, 132 (10) :1005-1009
[4]   Electrochemical sensors [J].
Bakker, Eric ;
Qin, Yu .
ANALYTICAL CHEMISTRY, 2006, 78 (12) :3965-3983
[5]  
BARD AJ, 2003, INSTRUMENTATION ELEC, V3, pCH1
[6]  
Barsoukov E, 2005, IMPEDANCE SPECTROSCOPY: THEORY, EXPERIMENT, AND APPLICATIONS, 2ND EDITION, pXII
[7]   On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy [J].
Bart, M ;
Stigter, ECA ;
Stapert, HR ;
de Jong, GJ ;
van Bennekom, WP .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :49-59
[8]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[9]  
2-B
[10]  
Bott AW., 2001, Curr, V19, P71