Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip

被引:60
作者
Dahlin, AP
Wetterhall, M
Liljegren, G
Bergström, SK
Andrén, P
Nyholm, L
Markides, KE
Bergquist, J
机构
[1] Uppsala Univ, Dept Analyt Chem, S-75124 Uppsala, Sweden
[2] Uppsala Univ, Lab Biol & Med Mass Spectrometry, S-75124 Uppsala, Sweden
[3] Uppsala Univ, Dept Chem Mat, Angstrom Lab, S-75121 Uppsala, Sweden
关键词
D O I
10.1039/b414592e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hybrid capillary-poly(dimethysiloxane) (PDMS) microchips with integrated electrospray ionization (ESI) tips were directly fabricated by casting PDMS in a mould. The shapes of the emitter tips were drilled into the mould, which produced highly reproducible three-dimensional tips. Due to the fabrication method of the microfluidic devices, no sealing was necessary and it was possible to produce a perfect channel modified by PolyE-323, an aliphatic polyamine coating agent. A variety of different coating procedures were also evaluated for the outside of the emitter tip. Dusting graphite on a thin unpolymerised PDMS layer followed by polymerisation was proven to be the most suitable procedure. The emitter tips showed excellent electrochemical properties and durabilities. The coating of the emitter was eventually passivated, but not lost, and could be regenerated by electrochemical means. The excellent electrochemical stability was further confirmed in long term electrospray experiments, in which the emitter sprayed continuously for more than 180 h. The PolyE-323 was found suitable for systems that integrate rigid fused silica and soft PDMS technology, since it simply could be applied successfully to both materials. The spray stability was confirmed from the recording of a total ion chromatogram in which the electrospray current exhibited a relative standard deviation of 3.9% for a 30 min run. CE-ESI-MS separations of peptides were carried out within 2 min using the hybrid PDMS chip resulting in similar efficiencies as for fused silica capillaries of the same length and thus with no measurable band broadening effects, originating from the PDMS emitter.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 41 条
[1]   Development of a poly(dimethylsiloxane) interface for on-line capillary column liquid chromatography-capillary electrophoresis coupled to sheathless electrospray ionization time-of-flight mass spectrometry [J].
Bergström, SK ;
Samskog, J ;
Markides, KE .
ANALYTICAL CHEMISTRY, 2003, 75 (20) :5461-5467
[2]  
BERGSTROM SK, IN PRESS ANAL CHEM
[3]  
Chartogne A, 2000, RAPID COMMUN MASS SP, V14, P1269, DOI 10.1002/1097-0231(20000730)14:14<1269::AID-RCM24>3.0.CO
[4]  
2-F
[5]  
Chen SH, 2001, ELECTROPHORESIS, V22, P3972, DOI 10.1002/1522-2683(200110)22:18<3972::AID-ELPS3972>3.0.CO
[6]  
2-6
[7]   Micro devices integrated with microchannels and electrospray nozzles using PDMS casting techniques [J].
Chiou, CH ;
Lee, GB ;
Hsu, HT ;
Chen, PW ;
Liao, PC .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3) :280-286
[8]   Chip-MS: Coupling the large with the small [J].
de Mello, AJ .
LAB ON A CHIP, 2001, 1 (01) :7N-12N
[9]  
FIGEYS D, 1999, J CAPILLARY ELECTROP, V6, P1
[10]   Integrated microfluidic system enabling protein digestion, peptide separation, and protein identification [J].
Gao, J ;
Xu, JD ;
Locascio, LE ;
Lee, CS .
ANALYTICAL CHEMISTRY, 2001, 73 (11) :2648-2655