Fluorescence lifetime imaging of unstained tissues: early results in human breast cancer

被引:112
作者
Tadrous, PJ
Siegel, J
French, PMW
Shousha, S
Lalani, EN
Stamp, GWH
机构
[1] Univ London Imperial Coll Sci Technol & Med, Hammersmith Hosp, Sch Med,ICSM, Dept Histopathol, London W12 0NN, England
[2] ICSM, Dept Phys, Femtosecond Opt Grp, London, England
[3] Charing Cross Hosp, ICSM, Dept Histopathol, London, England
关键词
autofluorescence; time-domain; FLIM; breast; carcinoma; stroma;
D O I
10.1002/path.1286
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Fluorescence lifetime imaging (FLIM) depends on the fluorescence decay differences between tissues to generate image contrast. In the present study FLIM has been applied to fixed (but unstained) breast cancer tissues to demonstrate the feasibility of this approach for histopathological assessment. As the FLIM method relies on natural autofluorescence, it may be possible to circumvent tissue processing altogether and so FLIM has the potential to be a powerful new method of in vivo tissue imaging via an endoscopic or per-operative approach in a variety of organs, as well as a research tool for in vivo animal models of disease. Unstained, alcohol-fixed tissue samples from 13 patients were stimulated by laser pulses at 415 nm. The temporal decay of the autofluorescence was imaged over a period of 2 ns after cessation of the pulse. The decay rate at each image pixel was calculated as the `lifetime' factor tau. A tissue classification scheme was used to define regions in each image. The average lifetimes of different tissue regions were compared. A total of 167 tissue regions were measured. Within individual fields, stroma had a larger tau (slower decay) than epithelium (p < 0.001). Within individual patients (taking the mean T of a given tissue type across all fields from each patient), there was a statistically significant difference between benign and malignancy-associated stroma (p < 0.05). Also, benign collagen had a longer t than benign epithelium (p < 0.05). Multivariate analysis showed a significant difference between benign stroma, malignancy-associated stroma, blood vessels, and malignant epithelium (p < 0.05). Statistically significant differences between benign and malignancy-associated stroma were obtained even with small patient numbers, indicating that lifetime-based instruments can be developed for real-time diagnostic imaging with microscopic resolution. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:309 / 317
页数:9
相关论文
共 19 条
[1]  
Andersson-Engels S, 2000, LASER SURG MED, V26, P76, DOI 10.1002/(SICI)1096-9101(2000)26:1<76::AID-LSM11>3.0.CO
[2]  
2-4
[3]   SENSING OXYGEN THROUGH SKIN USING A RED DIODE-LASER AND FLUORESCENCE LIFETIMES [J].
BAMBOT, SB ;
RAO, G ;
ROMAULD, M ;
CARTER, GM ;
SIPIOR, J ;
TERPETCHNIG, E ;
LAKOWICZ, JR .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) :643-652
[4]   USE OF TIME-GATED FLUORESCENCE IMAGING FOR DIAGNOSIS IN BIOMEDICINE [J].
CUBEDDU, R ;
TARONI, P ;
VALENTINI, G ;
CANTI, G .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1992, 12 (01) :109-113
[5]   Time-resolved fluorescence and photon migration studies in biomedical and model random media [J].
Das, BB ;
Liu, F ;
Alfano, RR .
REPORTS ON PROGRESS IN PHYSICS, 1997, 60 (02) :227-292
[6]   Fluorescence lifetime imaging with picosecond resolution for biomedical applications [J].
Dowling, K ;
Dayel, MJ ;
Lever, MJ ;
French, PMW ;
Hares, JD ;
Dymoke-Bradshaw, AKL .
OPTICS LETTERS, 1998, 23 (10) :810-812
[7]  
JONES R, 1998, ELECTRON LETT, V35, P1
[8]  
LACKOWICZ JR, 1992, ANAL BIOCHEM, V202, P316
[9]   FLUORESCENCE LIFETIME IMAGING OF INTRACELLULAR CALCIUM IN COS CELLS USING QUIN-2 [J].
LAKOWICZ, JR ;
SZMACINSKI, H ;
LEDERER, WJ ;
KIRBY, MS ;
JOHNSON, ML ;
NOWACZYK, K .
CELL CALCIUM, 1994, 15 (01) :7-27
[10]   Application of the stretched exponential function to fluorescence lifetime imaging [J].
Lee, KCB ;
Siegel, J ;
Webb, SED ;
Lévêque-Fort, S ;
Cole, MJ ;
Jones, R ;
Dowling, K ;
Lever, MJ ;
French, PMW .
BIOPHYSICAL JOURNAL, 2001, 81 (03) :1265-1274