Quantitative LC-ESI-MS analysis for pesticides in a complex environmental matrix using external and internal standards

被引:9
作者
Choi, BK
Gusev, AI
Hercules, DM
机构
[1] Vanderbilt Univ, Dept Chem, Nashville, TN 37235 USA
[2] Rohm & Haas Co, Philadelphia, PA 19106 USA
关键词
LC-MS; pesticides; internal standards; quantitative analysis;
D O I
10.1080/03067310008032699
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative liquid chromatography electrospray mass spectrometry (LC-MS) analysis for pesticides in a complex environmental matrix using external and internal standard calibration was investigated. Various approaches to introducing different internal standard compounds to address quantitative errors associated with signal suppression were also examined. The study involved the analysis of pesticides in wheat hay matrix samples using three kinds of internal standard compounds: deuterium labeled (D-3) carbon-13 (singly labeled), and structural analogs (derivatives) of the target analytes. Introduction of the internal standard by volumetric addition and direct post-column infusion were also studied and compared. Isotopically labeled internal standards (i.e. D-3- C-13-) were found to be effective in correcting quantitative errors associated with signal suppression. The application of singly labeled C-13 compounds may result in nonlinear calibration due to mass interference with the target analyte species. The interference may be compensated by using quadratic curve-fitting or subtraction of the interfering component. Although ineffective as volumetric internal standards, structural analogs can be effective in compensating for signal suppression when introduced into the LC effluent by continuous post-column infusion. Furthermore, the post-column introduction method allows the application of a single internal standard compound for the quantification of each analyte in a multi-component mixture. The use of internal standards can be effectively incorporated into residue analysis development methods for pesticides in environmental matrices. High accuracy and reproducibility can be achieved while improving method efficiency by reducing the need for comprehensive sample clean-up.
引用
收藏
页码:305 / 322
页数:18
相关论文
共 13 条
[1]  
[Anonymous], 1998, J MASS SPECTROM SOC, DOI DOI 10.5702/MASSSPEC.46.235
[2]  
Balogh MP, 1998, LC GC-MAG SEP SCI, V16, P135
[3]   QUANTITATIVE TRACE ANALYSIS BY COMBINED CHROMATOGRAPHY AND MASS-SPECTROMETRY USING EXTERNAL AND INTERNAL STANDARDS [J].
BOYD, RK .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (04) :257-271
[4]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[5]  
CHOO DW, ROHM HAAS TECHNICAL
[6]  
Ferrer I, 1998, ANALUSIS, V26, pM118, DOI 10.1051/analusis:1998159
[7]   FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY [J].
KEBARLE, P ;
TANG, L .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :A972-A986
[8]   EFFECTS OF ANIONS ON THE POSITIVE-ION ELECTROSPRAY-IONIZATION MASS-SPECTRA OF PEPTIDES AND PROTEINS [J].
MIRZA, UA ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2898-2904
[9]   Application of secondary ion and matrix-assisted laser desorption-ionization time-of-flight mass spectrometry for the quantitative analysis of biological molecules [J].
Muddiman, DC ;
Gusev, AI ;
Hercules, DM .
MASS SPECTROMETRY REVIEWS, 1995, 14 (06) :383-429
[10]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - GENERAL-PRINCIPLES AND INSTRUMENTATION [J].
NIESSEN, WMA ;
TINKE, AP .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :37-57