Perfusion and chemical monitoring of living cells on a microfluidic chip

被引:124
作者
Shackman, JG
Dahlgren, GM
Peters, JL
Kennedy, RT [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
来源
LAB ON A CHIP | 2005年 / 5卷 / 01期
关键词
D O I
10.1039/b404974h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microfluidic device that incorporates continuous perfusion and an on-line electrophoresis immunoassay was developed, characterized, and applied to monitoring insulin secretion from single islets of Langerhans. In the device, a cell chamber was perfused with cell culture media or a balanced salt solution at 0.6 to 1.5 muL min(-1). The flow was driven by gas pressure applied off-chip. Perfusate was continuously sampled at 2 nL min(-1) by electroosmosis through a separate channel on the chip. The perfusate was mixed on-line with fluorescein isothiocyanate-labeled insulin (FITC-insulin) and monoclonal anti-insulin antibody and allowed to react for 60 s as the mixture traveled down a 4 cm long reaction channel. The cell chamber and reaction channel were maintained at 37 degreesC. The reaction mixture was injected onto a 1.5 cm separation channel as rapidly as every 6 s, and the free FITC-insulin and the FITC-insulin-antibody complex were separated under an electric field of 500 to 600 V cm(-1). The immunoassay had a detection limit of 0.8 nM and a relative standard deviation of 6% during 2 h of continuous operation with standard solutions. Individual islets were monitored for up to 1 h while perfusing with different concentrations of glucose. The immunoassay allowed quantitative monitoring of classical biphasic and oscillatory insulin secretion with 6 s sampling frequency following step changes in glucose from 3 to 11 mM. The 2.5 cm x 7.6 cm microfluidic system allowed for monitoring islets in a highly automated fashion. The technique should be amenable to studies involving other tissues or cells that release chemicals.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 30 条
[1]   GLUCOSE-INDUCED AMPLITUDE REGULATION OF PULSATILE INSULIN-SECRETION FROM INDIVIDUAL PANCREATIC-ISLETS [J].
BERGSTEN, P ;
HELLMAN, B .
DIABETES, 1993, 42 (05) :670-674
[2]   GLUCOSE-INDUCED CYCLES OF INSULIN RELEASE CAN BE RESOLVED INTO DISTINCT PERIODS OF SECRETORY ACTIVITY [J].
BERGSTEN, P ;
HELLMAN, B .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1993, 192 (03) :1182-1188
[3]  
BERGSTEN P, 1994, J BIOL CHEM, V269, P8749
[4]   Functional cellular assays with multiparametric silicon sensor chips [J].
Brischwein, M ;
Motrescu, ER ;
Cabala, E ;
Otto, AM ;
Grothe, H ;
Wolf, B .
LAB ON A CHIP, 2003, 3 (04) :234-240
[5]  
Dawson R.M. C., 2002, DATA BIOCH RES
[6]   Dielectrophoretic sorting of particles and cells in a microsystem [J].
Fiedler, S ;
Shirley, SG ;
Schnelle, T ;
Fuhr, G .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1909-1915
[7]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111
[8]   Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip [J].
Gao, J ;
Yin, XF ;
Fang, ZL .
LAB ON A CHIP, 2004, 4 (01) :47-52
[9]   Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing [J].
Gawad, S ;
Schild, L ;
Renaud, P .
LAB ON A CHIP, 2001, 1 (01) :76-82
[10]  
HARRIS D, 1995, QUANTITATIVE CHEM AN