Ultrasound Transducers for Large-Scale Metrology: A Performance Analysis for Their Use by the MScMS

被引:12
作者
Franceschini, Fiorenzo [1 ]
Maisano, Domenico [1 ]
Mastrogiacomo, Luca [1 ]
Pralio, Barbara [1 ]
机构
[1] Politecn Torino, Dept Mfg Syst & Business Econ DISPEA, I-10129 Turin, Italy
关键词
Dimensional measurements; factorial plan; large-scale metrology; signal attenuation; threshold detection; time of flight (TOF); ultrasound transducer; TIME; SYSTEM; RANGE; CALIBRATION; ACCURACY;
D O I
10.1109/TIM.2009.2022106
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Mobile Spatial coordinate Measuring System (MScMS) is a distributed wireless-sensor-network-based system used to perform dimensional measurements of large-scale objects. The system consists of a wireless mobile probe with ultrasonic (US) transceivers, the position of which is determined using a distributed constellation of US transceivers arranged around the measuring area. These US transceivers, which are known as Crickets, transmit US signals to each other and measure their time of flight (TOF) to determine the mutual distances. The MScMS is able to calculate the Cartesian coordinates of the object surface points touched by the wireless mobile probe. This paper aims to experimentally evaluate the performance of the US transducers on each of the MScMS Crickets. The experiments are designed and performed by means of a statistical factorial plan to identify the most important factors affecting the transducers' performance on TOF measurements. Particular attention is given to the error derived by the US signal attenuation and the method of US pulse detection. The results are analyzed in detail and fully interpreted. Finally, some considerations about possible actions to improve the MScMS measuring system are given.
引用
收藏
页码:110 / 121
页数:12
相关论文
共 33 条
[21]   Estimating the 3D-position from time delay data of US-waves:: experimental analysis and a new processing algorithm [J].
Martín, JM ;
Jiménez, AR ;
Seco, F ;
Calderón, L ;
Pons, JL ;
Ceres, R .
SENSORS AND ACTUATORS A-PHYSICAL, 2002, 101 (03) :311-321
[22]  
*MIT COMP SCI ART, 2004, CRICK V2 US MAN
[23]  
Montgomery D., 2013, DESIGN ANAL EXPT, V8
[24]   DIGITAL SIGNAL-PROCESSING TECHNIQUES FOR HIGH-ACCURACY ULTRASONIC RANGE MEASUREMENTS [J].
PARRILLA, M ;
ANAYA, JJ ;
FRITSCH, C .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) :759-763
[25]   Locating the nodes [J].
Patwari, N ;
Ash, JN ;
Kyperountas, S ;
Hero, AO ;
Moses, RL ;
Correal, NS .
IEEE SIGNAL PROCESSING MAGAZINE, 2005, 22 (04) :54-69
[26]   Improving the accuracy of ultrasound-based localisation systems [J].
Piontek, Hubert ;
Seyffer, Matthias ;
Kaiser, Joerg .
PERSONAL AND UBIQUITOUS COMPUTING, 2007, 11 (06) :439-449
[27]  
Priyantha N., 2000, Proceedings of the 6th Annual International Conference on Mobile Computing and Networking. MobiCom'00, P32, DOI [10.1145/345910.345917, DOI 10.1145/345910.345917]
[28]  
Priyantha NB, 2005, IEEE INFOCOM SER, P172
[29]  
PUTTOCK MJ, 1978, ANN CIRP, V21, P351
[30]  
Shnayder Victor., 2004, P 2 INT C EMBEDDED N, P188, DOI DOI 10.1145/1031495.1031518