Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography

被引:61
作者
Ciatto, S
Del Turco, MR
Risso, G
Catarzi, S
Bonardi, R
Viterbo, V
Gnutti, P
Guglielmoni, B
Pinelli, L
Pandiscia, A
Navarra, F
Lauria, A
Palmiero, R
Indovina, PL
机构
[1] Ctr Studio & Prevenz Oncol, I-50131 Florence, Italy
[2] Univ Bari, Inst Radiol, Bari, Italy
[3] Brescia Hosp, Dept Radiol, Brescia, Italy
[4] Melegnano Hosp, Dept Radiol, Melegnano, Italy
[5] Frosinone Hosp, Dept Radiol, Frosinone, Italy
[6] Cernusco Hosp, Dept Radiol, Cernusco Sul Naviglio, Italy
[7] Teramo Hosp, Dept Radiol, Teramo, Italy
[8] Univ Naples Federico II, Dipartimento Sci Fis, Naples, Italy
关键词
mammography; diagnosis; breast cancer; computer aided diagnosis;
D O I
10.1016/S0720-048X(02)00011-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the role of computer aided detection (CAD) in improving the interpretation of screening mammograms Material and methods: Ten radiologists underwent a proficiency test of screening mammography first by conventional reading and then with the help of CAD. Radiologists were blinded to test results for the whole study duration. Results of conventional and CAD reading were compared in terms of sensitivity and recall rate. Double reading was simulated combining conventional readings of four expert radiologists and compared with CAD reading. Results: Considering all ten readings, cancer was identified in 146 or 153 of 170 cases (85.8 vs. 90.0%; chi(2) = 0.99, df = 1, P = 0.31) and recalls were 106 or 152 of 1330 cases (7.9 vs. 11.4%; chi(2) = 8.69, df = 1, P = 0.003) at conventional or CAD reading, respectively. CAD reading was essentially the same (sensitivity 97.0 vs. 96.0%; chi(2)=7.1, df = 1, P=0.93; recall rate 10.7 vs. 10.6%; chi(2) = 1.5, df= 1, P=0.96) as compared with simulated conventional double reading. Conclusion: CAD reading seems to improve the sensitivity of conventional reading while reducing specificity, both effects being of limited size. CAD reading had almost the same performance of simulated conventional double reading, suggesting a possible use of CAD which needs to be confirmed by further studies inclusive of cost-effective analysis. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:135 / 138