Novel oxygen sensitive complexes for optical oxygen sensing

被引:41
作者
Fernandez-Sanchez, J. F.
Roth, T.
Cannas, R.
Nazeeruddin, Md. K.
Spichiger, S.
Graetzel, M.
Spichiger-Keller, U. E.
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
[2] ETHZ, Ctr Chem Sensors, Swiss Fed Inst Technol, CH-8005 Zurich, Switzerland
[3] Ecole Polytech Fed Lausanne, Lab Photon & Interfaces, Inst Chem Sci & Engn, CH-1015 Lausanne, Switzerland
关键词
optical sensor; luminescence; oxygen; ruthenium complex; iridium complex; sterilization;
D O I
10.1016/j.talanta.2006.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel optical sensing films for oxygen based on highly luminescent iridium (111) and ruthenium (11) complexes have been developed. These demonstrate excellent long-term photostability (several months) when incorporated into polystyrene membranes. The influence of different plasticizers on the specific luminescence quantum yield, the Stern-Volmer constant, the reversibility and the response time were evaluated. Additionally the sensing films can be sterilized by chemical cleaning and gamma-ray irradiation. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 250
页数:9
相关论文
共 45 条
[1]   Comparative assessment of chemical and γ-irradiation procedures for implantable glucose enzyme electrodes [J].
Ahmed, S ;
Rigby, GP ;
Crump, P ;
Vadgama, PM .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :159-165
[2]   Probes and polymers for optical sensing of oxygen [J].
Amao, Y .
MICROCHIMICA ACTA, 2003, 143 (01) :1-12
[3]   Green luminescent iridium(III) complex immobilized in fluoropolymer film as optical oxygen-sensing material [J].
Amao, Y ;
Ishikawa, Y ;
Okura, I .
ANALYTICA CHIMICA ACTA, 2001, 445 (02) :177-182
[4]   Metalloporphyrins immobilized in styrene-trifluoroethylmethacrylate copolymer film as an optical oxygen sensing probe [J].
Amao, Y ;
Miyashita, T ;
Okura, I .
JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2001, 5 (05) :433-438
[5]   Fluorescence quenching oxygen sensor using an aluminum phthalocyanine-polystyrene film [J].
Amao, Y ;
Asai, K ;
Okura, I .
ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) :41-44
[6]   Characterization of microtiterplates with integrated optical sensors for oxygen and pH, and their applications to enzyme activity screening, respirometry, and toxicological assays [J].
Arain, S ;
John, GT ;
Krause, C ;
Gerlach, J ;
Wolfbeis, OS ;
Klimant, I .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :639-648
[7]   A MICRO-HOLE POTENTIOSTATIC OXYGEN SENSOR FOR OCEANIC CTDS [J].
ATKINSON, MJ ;
THOMAS, FIM ;
LARSON, N ;
TERRILL, E ;
MORITA, K ;
LIU, CC .
DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 1995, 42 (05) :761-&
[8]   In vivo phosphorescence imaging of pO2 using planar oxygen sensors [J].
Babilas, P ;
Liebsch, G ;
Schacht, V ;
Klimant, I ;
Wolfbeis, OS ;
Szeimies, RM ;
Abels, C .
MICROCIRCULATION, 2005, 12 (06) :477-487
[9]   Single standard calibration for an optical oxygen sensor based on luminescence quenching of a ruthenium complex [J].
Choi, MMF ;
Xiao, D .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :57-65
[10]  
Clark LC, 1959, U.S. Patent, Patent No. 2913386