Ammonium hydrogencarbonate buffer has been found to be especially useful for high-pH HPLC analysis of samples from both combinatorial and medicinal chemistry sources. Satisfactory results were obtained by the standard diode array, evaporative light-scattering, and MS detection by using this buffer at a concentration of 10 mM. From a practical standpoint, ammonium hydrogencarbonate is an ideal buffer for chromatographers since it provides excellent chromatographic behaviour and reproducible separation. In addition to this, its volatility makes it an essential tool for rapid LC-MS product identification. Ammonium hydrogencarbonate was tested for a number of drug-like compounds analysed as mixtures, and data obtained were compared to those from the classical and MS-friendly buffers widely used by chromatographers: trifluoroacetic and formic acids. The results of this study revealed the suitability of this buffer for routine HPLC application in research laboratories. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 33 条
[1]  
BOSCH G, 2000, COMMUNICATION
[2]  
Buszewski B, 1998, HRC-J HIGH RES CHROM, V21, P267
[3]   Retention of ionizable compounds on HPLC.: 8.: Influence of mobile-phase pH change on the chromatographic retention of acids and bases during gradient elution [J].
Canals, I ;
Valkó, K ;
Bosch, E ;
Hill, AP ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4937-4945
[4]   AMMONIUM BICARBONATE MEDIATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY RESOLUTION OF BIS-ANTHRACYCLINES [J].
CHANDLER, CJ ;
PHILLIPS, DR ;
BROWNLEE, RTC ;
REISS, JA .
JOURNAL OF CHROMATOGRAPHY, 1986, 358 (01) :179-186
[5]  
Choi BK, 2002, LC GC N AM, V20, P152
[6]   Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography [J].
Claessens, HA ;
vanStraten, MA ;
Kirkland, JJ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :259-270
[7]  
DOLAN JW, 2001, LC GC EUR, V12, P1132
[8]   Comprehensive survey of combinatorial library synthesis: 1999 [J].
Dolle, RE .
JOURNAL OF COMBINATORIAL CHEMISTRY, 2000, 2 (05) :383-433
[9]  
ESPADA A, 2001, UNPUB
[10]   Retention of ionizable compounds in high-performance liquid chromatography IX.: Modelling retention in reversed-phase liquid chromatography as a function of pH and solvent composition with acetonitrile-water mobile phases [J].
Espinosa, S ;
Bosch, E ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 947 (01) :47-58