Computerized optimization of multiple isocentres in stereotactic convergent beam irradiation

被引:12
作者
Treuer, U [1 ]
Treuer, H
Hoevels, M
Muller, RP
Sturm, V
机构
[1] Univ Klin Koln, Abt Stereotaxie & Funkt Neurochirurg, Cologne, Germany
[2] Univ Klin Koln, Strahlentherapeut Klin, Cologne, Germany
[3] Howmedica Leibinger GMBH, Freiburg, Germany
关键词
D O I
10.1088/0031-9155/43/1/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for the fully computerized determination and optimization of positions of target points and collimator sizes in convergent beam irradiation is presented. In conventional interactive trial and error methods, which are very time consuming, the treatment parameters are chosen according to the operator's experience and improved successively. This time is reduced significantly by the use of a computerized procedure. After the definition of target volume and organs at risk in the CT or MR scans, an initial configuration is created automatically. In the next step the target point positions and collimator diameters are optimized by the program. The aim of the optimization is to find a configuration for which a prescribed dose at the target surface is approximated as close as possible. At the same time dose peaks inside the target volume are minimized and organs at risk and tissue surrounding the target are spared. To enhance the speed of the optimization a fast method for approximate dose calculation in convergent beam irradiation is used. A possible application of the method for calculating the leaf positions when irradiating with a micromultileaf collimator is briefly discussed. The success of the procedure has been demonstrated for several clinical cases with up to six target points.
引用
收藏
页码:49 / 64
页数:16
相关论文
共 19 条
[1]   COMPUTERIZED OPTIMIZATION OF I125 IMPLANTS IN BRAIN-TUMORS [J].
BAUERKIRPES, B ;
STURM, V ;
SCHLEGEL, W ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (05) :1013-1023
[2]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[3]   EXTERNAL STEREOTACTIC IRRADIATION BY LINEAR-ACCELERATOR [J].
COLOMBO, F ;
BENEDETTI, A ;
POZZA, F ;
AVANZO, RC ;
MARCHETTI, C ;
CHIEREGO, G ;
ZANARDO, A .
NEUROSURGERY, 1985, 16 (02) :154-160
[4]   TREATMENT PLANNING FOR GAMMA KNIFE RADIOSURGERY WITH MULTIPLE ISOCENTERS [J].
FLICKINGER, JC ;
LUNSFORD, LD ;
WU, A ;
MAITZ, AH ;
KALEND, AM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06) :1495-1501
[5]  
Goetsch SJ, 1993, STEREOTACTIC SURG RA, P277
[6]   CEREBRAL RADIATION SURGERY USING MOVING FIELD IRRADIATION AT A LINEAR-ACCELERATOR FACILITY [J].
HARTMANN, GH ;
SCHLEGEL, W ;
STURM, V ;
KOBER, B ;
PASTYR, O ;
LORENZ, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (06) :1185-1192
[7]   TREATMENT PLANNING OPTIMIZATION FOR MULTIPLE ARCS STEREOTAXIC RADIOSURGERY USING A LINEAR-ACCELERATOR [J].
LAM, CF ;
ZHU, JG ;
PENN, JO ;
JENRETTE, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (03) :647-657
[8]   A SYSTEM FOR STEREOTACTIC RADIOSURGERY WITH A LINEAR-ACCELERATOR [J].
LUTZ, W ;
WINSTON, KR ;
MALEKI, N .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (02) :373-381
[9]   AN ADJUSTABLE COLLIMATOR FOR STEREOTAXIC RADIOSURGERY [J].
MCGINLEY, PH ;
BUTKER, EK ;
CROCKER, IR ;
AIKEN, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :413-419
[10]   VARIABLES ASSOCIATED WITH THE DEVELOPMENT OF COMPLICATIONS FROM RADIOSURGERY OF INTRACRANIAL TUMORS [J].
NEDZI, LA ;
KOOY, H ;
ALEXANDER, E ;
GELMAN, RS ;
LOEFFLER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :591-599