Real-time nucleic acid amplification methods can be extremely useful for the identification and quantitation of nucleic acid analytes, but are more difficult to adapt to protein or other analytes. To facilitate the development of real-time rolling circle amplification (RCA) for protein targets, we have developed a novel type of conformation-switching aptamer that can be circularized upon interaction with its protein target, the platelet-derived growth factor (PDGF). Using the structure-switching aptamer, real-time RCA can be used to specifically quantitate PDGF down to the low-nanomolar range (limit of detection, 0.4 nM), even against a background of cellular lysate. The aptamer can also be adapted to RCA on surfaces, although quantitation proved to be more difficult. One of the great advantages of the method described herein is that it can be immediately adapted to almost any aptamer and does not require two or more affinity reagents as do sandwich or proximity assays.
引用
收藏
页码:3320 / 3329
页数:10
相关论文
共 52 条
[1]   Displacement enzyme linked aptamer assay [J].
Baldrich, E ;
Acero, JL ;
Reekmans, G ;
Laureyn, W ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2005, 77 (15) :4774-4784
[2]   Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[3]  
Barletta Janet, 2006, Molecular Aspects of Medicine, V27, P224, DOI 10.1016/j.mam.2005.12.008
[4]   Programmable ligand-controlled riboregulators of eukaryotic gene expression [J].
Bayer, TS ;
Smolke, CD .
NATURE BIOTECHNOLOGY, 2005, 23 (03) :337-343
[5]  
BOWENPOPE DF, 1984, BLOOD, V64, P458
[6]   Aptamers come of age - at last [J].
Bunka, David H. J. ;
Stockley, Peter G. .
NATURE REVIEWS MICROBIOLOGY, 2006, 4 (08) :588-596
[7]   Using a deoxyribozyme ligase and rolling circle amplification to detect a non-nucleic acid analyte, ATP [J].
Cho, EJ ;
Yang, LT ;
Levy, M ;
Ellington, AD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (07) :2022-2023
[8]  
Cho EJ, 2005, T FLUOR SP, V10, P127
[9]   Proximity extension of circular DNA aptamers with real-time protein detection [J].
Di Giusto, DA ;
Wlassoff, WA ;
Gooding, JJ ;
Messerle, BA ;
King, GC .
NUCLEIC ACIDS RESEARCH, 2005, 33 (06) :1-7
[10]   Real-time PCR in clinical microbiology: Applications for a routine laboratory testing [J].
Espy, MJ ;
Uhl, JR ;
Sloan, LM ;
Buckwalter, SP ;
Jones, MF ;
Vetter, EA ;
Yao, JDC ;
Wengenack, NL ;
Rosenblatt, JE ;
Cockerill, FR ;
Smith, TF .
CLINICAL MICROBIOLOGY REVIEWS, 2006, 19 (01) :165-+