Absence of acute adverse in-vitro effects on AS-1 RBCs and whole blood-derived platelets following prolonged exposure to 13.56 MHz radio energy

被引:10
作者
Davis, Rodeina [1 ]
Gottschall, Jerome
Gutierrez, Alfonso
Hohberger, Clive
Veeramani, Dharmaraj
Holcombe, Jerry [1 ]
机构
[1] BloodCtr Wisconsin, Milwaukee, WI 53233 USA
基金
美国国家卫生研究院;
关键词
FREQUENCY IDENTIFICATION; TRANSFUSIONS;
D O I
10.1111/j.1537-2995.2010.02733.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: There is growing interest in radio frequency identification (RFID) technology application for tracking blood products to achieve higher productivity and safety in the transfusion medicine supply chain. We have conducted a limited study to assess the temperature and biological effects of 13.56 MHz RF radiation on RBCs and whole blood-derived platelets (WBDP) under extreme exposure conditions. STUDY DESIGN AND METHODS: Using an FDA-approved protocol, test units of both RBC and WBDP were subjected to approximately 100 watts of RF energy for an extended duration (23-25 h) to assess worst-case effects. Three replications of the test were performed. RESULTS: Hemolysis after 23-25 hours of RF energy exposure was 0.09% and 0.05%, respectively, for TEST and CONTROL RBC units and well within the < 1% limit in the FDA-approved acceptance criteria. For WBDP units, the mean pH of TEST and CONTROL units were 7.27 and 7.19, respectively, following 23-25 hours of RF energy exposure, and well above the >= 6.2 acceptance limit. Further, there was no detectable acceleration in cellular degradation of RBC and WBDP products. While there was minimal temperature rise, the relative temperature increase between TEST and CONTROL units never exceeded the 1.5 degrees C acceptance criterion. CONCLUSIONS: 13.56 MHz-based RFID technology is unlikely to have any significant temperature or biological effects on RBC and WBDP units under the normal operating conditions (a maximum of 4 watts RF power exposure for about 20 nonconsecutive minutes for RFID tracking during the life of the blood product).
引用
收藏
页码:1596 / 1603
页数:8
相关论文
共 9 条
[1]  
DOLS JL, 2008, USING LOCATION TIME
[2]   Platelet surface P-selectin measurements in platelet preparations: An international collaborative study [J].
Dumont, LJ ;
VandenBroeke, T ;
Ault, KA .
TRANSFUSION MEDICINE REVIEWS, 1999, 13 (01) :31-42
[3]  
DZIK S, 2006, IDTECHEX RFID SMART
[4]   Radio frequency identification for prevention of bedside errors [J].
Dzik, Sunny .
TRANSFUSION, 2007, 47 (02) :125S-129S
[5]  
Hohberger Clive P., 2009, International Journal of Radio Frequency Identification Technology and Applications, V2, P65, DOI 10.1504/IJRFITA.2009.023483
[6]   Radio frequency identification (RFID): an experience in transfusion medicine [J].
Knels, R. .
ISBT SCIENCE SERIES, VOL 1, NO 1: STATE OF THE ART PRESENTATIONS, 2006, 1 (01) :238-241
[7]  
Lusky K, 2005, CAP TODAY JUL, P45
[8]   Radiofrequency identification technology can standardize and document blood collections and transfusions [J].
Sandler, S. Gerald ;
Langeberg, Al ;
DeBandi, Leo ;
Gibble, Joan ;
Wilson, Charles ;
Feldman, Charles L. .
TRANSFUSION, 2007, 47 (05) :763-770
[9]   Bar code and radio-frequency technologies can increase safety and efficiency of blood transfusions [J].
Sandler, SG ;
Langeberg, A ;
Carty, K ;
Dohnalek, LJ .
LABMEDICINE, 2006, 37 (07) :436-439