An amperometric hydrogen peroxide biosensor based on immobilizing horseradish peroxidase to a nano-Au monolayer supported by sol-gel derived carbon ceramic electrode

被引:141
作者
Lei, CX
Hu, SQ
Gao, N
Shen, GL
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Peoples R China
[2] Hunan City Univ, Dept Chem & Environm Engn, Yiyang 413049, Peoples R China
[3] Zhuzhou Teachers Coll, Dept Chem, Zhuzhou 412007, Peoples R China
基金
中国国家自然科学基金;
关键词
amperometric biosensor; horseradish peroxidase; nano-Au monolayer; hydrogen peroxide;
D O I
10.1016/j.bioelechem.2004.06.002
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A novel strategy for fabricating horseradish peroxidase (HRP)-based H2O2 sensor has been developed by combining the merits of carbon sol-gel supporting matrix and nano-scaled particulate gold (nano-Au) mediator. The thiol functional group-derived carbon ceramic electrode (CCE) was first constructed using (3-mercaptopropyl) trimethoxy silane as sol-gel monomer. Then, the stable nano-Au monolayer was obtained through covalent linkage between nano-Au and thiol group on the surface of CCE. The experimental results showed that nano-Au monolayer formed not only could steadily immobilize HRP but also efficiently retain its bioactivity. Hydrogen peroxide was detected with the aid of hydroquinone mediator to transfer electrons between the electrode and HRP. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as the operating potential, mediator concentration and pH of background electrolyte were explored for optimum analytical performance of the enzyme electrode. The biosensor had a fast response of less than 8 s with linear range of 1.22 x 10(-5) to 1.10 x 10(-3) mol l(-1) and a detection limit of 6.1 x 10(-6) mol l(-1). The sensitivity of the sensor for H2O2 was 0.29 A l mol(-1) cm(-2). The activation energy for enzyme reaction was calculated to be 10.1 kJ mol(-1). The enzyme electrode retained 75% of its initial activity after 5 weeks storage in phosphate buffer at pH 7. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 39
页数:7
相关论文
共 35 条
[1]   An electrochemical multienzymatic biosensor for determination of cholesterol [J].
Bongiovanni, C ;
Ferri, T ;
Poscia, A ;
Varalli, M ;
Santucci, R ;
Desideri, A .
BIOELECTROCHEMISTRY, 2001, 54 (01) :17-22
[2]   Morphology-dependent electrochemistry of cytochrome c at Au colloid-modified SnO2 electrodes [J].
Brown, KR ;
Fox, AP ;
Natan, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (05) :1154-1157
[3]   Sol-gel-derived titanium oxide/copolymer composite based glucose biosensor [J].
Chen, X ;
Dong, SJ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (08) :999-1004
[4]   Reagentless amperometric determination of hydrogen peroxide by silica sol-gel modified biosensor [J].
Chut, SL ;
Li, J ;
Tan, SN .
ANALYST, 1997, 122 (11) :1431-1434
[5]   COLLOIDAL GOLD AS A BIOCOMPATIBLE IMMOBILIZATION MATRIX SUITABLE FOR THE FABRICATION OF ENZYME ELECTRODES BY ELECTRODEPOSITION [J].
CRUMBLISS, AL ;
PERINE, SC ;
STONEHUERNER, J ;
TUBERGEN, KR ;
ZHAO, JG ;
HENKENS, RW .
BIOTECHNOLOGY AND BIOENGINEERING, 1992, 40 (04) :483-490
[6]   Immobilisation of glucose oxidase within metallic nanotubes arrays for application to enzyme biosensors [J].
Delvaux, M ;
Demoustier-Champagne, S .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :943-951
[7]   ORGANIZATION OF AU COLLOIDS AS MONOLAYER FILMS ONTO ITO GLASS SURFACES - APPLICATION OF THE METAL COLLOID FILMS AS BASE INTERFACES TO CONSTRUCT REDOX-ACTIVE MONOLAYERS [J].
DORON, A ;
KATZ, E ;
WILLNER, I .
LANGMUIR, 1995, 11 (04) :1313-1317
[8]   Selective colorimetric detection of polynucleotides based on the distance-dependent optical properties of gold nanoparticles [J].
Elghanian, R ;
Storhoff, JJ ;
Mucic, RC ;
Letsinger, RL ;
Mirkin, CA .
SCIENCE, 1997, 277 (5329) :1078-1081
[9]   Improved mediated tyrosinase amperometric enzyme electrodes [J].
Hedenmo, M ;
Narvaez, A ;
Dominguez, E ;
Katakis, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 425 (1-2) :1-11
[10]  
HERANDEZSANTOS D, 2002, ELECTROANAL, V18, P1225