Influence of transforming growth factor-β3 on fibrous capsule formation around microgrooved subcutaneous implants in vivo

被引:17
作者
Gehrke, TAE
Walboomers, XF
Jansen, JA
机构
[1] Univ Nijmegen, Fac Med Sci, Coll Dent Sci, Dept Biomat, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Fac Med Sci, Coll Dent Sci, Dept Periodontol, NL-6500 HB Nijmegen, Netherlands
来源
TISSUE ENGINEERING | 2000年 / 6卷 / 05期
关键词
D O I
10.1089/107632700750022152
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Previous studies have shown that addition of transforming growth factor-beta3 (TGF-beta3) is capable of reducing scar tissue formation in skin defects. Therefore, are examined whether TGF-beta3 can also influence the organization of a fibrous capsule around implants in vivo. For this reason, 24 silicone implants with microgrooves with a groove depth of 1.0 mum and a ridge and groove width of 10.0 mum were made and loaded with human recombinant TGF-beta3 (0, 5, 50, and 250 ng). An in vitro release enzyme-linked immunosorbent assay (ELISA) test was done with another 10 implants to estimate the amount of TGF released from the implants. The implants were inserted subcutaneously in the backs of 6 guinea pigs. Each animal received four implants, which were left in place for 10 weeks. At the end of the implantation time, the implants were retrieved, embedded, and processed for histology. Histomorphometrical measurements were done on the capsule formation and the implant-cell interface quality and quantity. The results showed a fibrous capsule of 15 mum up to 50 mum thickness around all implants. There were no significant differences between the TGF-beta3-loaded implants or the controls. Frequently, inflammatory cells were present in the capsule. The implant-tissue interface was on average between 5 and 15 mum thick and consisted mostly out of one or two layers of macrophages or foreign body giant cells. Statistical analysis again showed no significant differences between the various TGF-beta3-coated implants and controls. Finally, we concluded that a microtextured surface can indeed be used for the release of TGF-beta3. On the other hand, this did not result in major differences in wound healing between implants loaded with 5, 50, or 250 ng of TGF-beta3 and controls.
引用
收藏
页码:505 / 517
页数:13
相关论文
共 28 条
[1]  
Brunette D., 1996, NANOFABRICATION BIOS, P335
[2]  
Campbell C E, 1989, J Invest Surg, V2, P51, DOI 10.3109/08941938909016503
[3]   EFFECTS OF A GROOVED TITANIUM-COATED IMPLANT SURFACE ON EPITHELIAL-CELL BEHAVIOR INVITRO AND INVIVO [J].
CHEHROUDI, B ;
GOULD, TRL ;
BRUNETTE, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (09) :1067-1085
[4]   A LIGHT AND ELECTRON-MICROSCOPIC STUDY OF THE EFFECTS OF SURFACE-TOPOGRAPHY ON THE BEHAVIOR OF CELLS ATTACHED TO TITANIUM-COATED PERCUTANEOUS IMPLANTS [J].
CHEHROUDI, B ;
GOULD, TRL ;
BRUNETTE, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (03) :387-405
[5]   TITANIUM-COATED MICROMACHINED GROOVES OF DIFFERENT DIMENSIONS AFFECT EPITHELIAL AND CONNECTIVE-TISSUE CELLS DIFFERENTLY INVIVO [J].
CHEHROUDI, B ;
GOULD, TRL ;
BRUNETTE, DM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (09) :1203-1219
[6]  
COX DA, 1995, CELL BIOL INT, V19, P357, DOI 10.1006/cbir.1995.1082
[7]  
denBraber ET, 1997, J BIOMED MATER RES, V37, P539, DOI 10.1002/(SICI)1097-4636(19971215)37:4<539::AID-JBM13>3.0.CO
[8]  
2-3
[9]   SKIN WOUND-HEALING - TRANSFORMING GROWTH-FACTOR-BETA ANTAGONISTS DECREASE SCARRING AND IMPROVE QUALITY [J].
FERGUSON, MWJ .
JOURNAL OF INTERFERON RESEARCH, 1994, 14 (05) :303-304
[10]   Scar formation: The spectral nature of fetal and adult wound repair [J].
Ferguson, MWJ ;
Whitby, DJ ;
Shah, M ;
Armstrong, J ;
Siebert, JW ;
Longaker, MT .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 97 (04) :854-860