Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases

被引:55
作者
Solná, R
Dock, E
Christenson, A
Winther-Nielsen, M
Carlsson, C
Emnéus, J
Ruzgas, T
Skládal, P
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[3] DHI Water & Environm, DK-2970 Horsholm, Denmark
[4] ANOX, S-22647 Lund, Sweden
关键词
amperometric multienzyme sensor; steady state system; cholinesterase; oxidoreductase; phenoks; pesticides; wastewater; multivariate-analysis;
D O I
10.1016/j.aca.2004.10.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiose dehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx). All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates (10 measurements) were typically below 7% and one assay was completed within less than 10 min. The detection limits for pesticides and phenols were in the nanomolar and micromolar ranges, respectively. The developed biosensor array was evaluated on wastewater samples. To simplify interpretation of results. the measured data were created with multivariate analysis-principal component analysis (PCA). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 19
页数:11
相关论文
共 39 条
  • [11] Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors
    Gogol, EV
    Evtugyn, GA
    Marty, JL
    Budnikov, HC
    Winter, VG
    [J]. TALANTA, 2000, 53 (02) : 379 - 389
  • [12] Direct electron transfer between heme-containing enzymes and electrodes as basis for third generation biosensors
    Gorton, L
    Lindgren, A
    Larsson, T
    Munteanu, FD
    Ruzgas, T
    Gazaryan, I
    [J]. ANALYTICA CHIMICA ACTA, 1999, 400 : 91 - 108
  • [13] CELLOBIOSE OXIDASE FROM PHANEROCHAETE-CHRYSOSPORIUM CAN BE CLEAVED BY PAPAIN INTO 2 DOMAINS
    HENRIKSSON, G
    PETTERSSON, G
    JOHANSSON, G
    RUIZ, A
    UZCATEGUI, E
    [J]. EUROPEAN JOURNAL OF BIOCHEMISTRY, 1991, 196 (01): : 101 - 106
  • [14] A critical review of cellobiose dehydrogenases
    Henriksson, G
    Johansson, G
    Pettersson, G
    [J]. JOURNAL OF BIOTECHNOLOGY, 2000, 78 (02) : 93 - 113
  • [15] Amperometric phenol biosensor based on sol-gel silicate/Nafion composite film
    Kim, MA
    Lee, WY
    [J]. ANALYTICA CHIMICA ACTA, 2003, 479 (02) : 143 - 150
  • [16] A convenient method for oxidation of organophosphorus pesticides in organic solvents
    Kim, YA
    Lee, HS
    Park, YC
    Lee, YT
    [J]. ENVIRONMENTAL RESEARCH, 2000, 84 (03) : 303 - 309
  • [17] Electronic tongues for environmental monitoring based on sensor arrays and pattern recognition:: a review
    Krantz-Rülcker, C
    Stenberg, M
    Winquist, F
    Lundström, I
    [J]. ANALYTICA CHIMICA ACTA, 2001, 426 (02) : 217 - 226
  • [18] LINGREN A, 1999, ANALYST, V124, P527
  • [19] DEVELOPMENT OF ENZYME-BASED AMPEROMETRIC SENSORS FOR THE DETERMINATION OF PHENOLIC-COMPOUNDS
    MARKOVARGA, G
    EMNEUS, J
    GORTON, L
    RUZGAS, T
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) : 319 - 328
  • [20] Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate
    Marquette, CA
    Degiuli, A
    Blum, LJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (05) : 433 - 439