Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine

被引:230
作者
Renner, Susan M.
Natarajan, Raghu N. [1 ]
Patwardhan, Avinash G.
Havey, Robert M.
Voronov, Leonard I.
Guo, Bev Y.
Andersson, Gunnar B. J.
An, Howard S.
机构
[1] Univ Illinois, Chicago, IL 60680 USA
[2] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL USA
[3] Loyola Univ, Ctr Med, Dept Orthoped Surg & Rehabil, Maywood, IL USA
[4] Edward Hines Jr, Dept Vet Affairs, Musculoskeletal Biomech Lab, Hines, IL USA
关键词
follower load; lumbar spine; kinematics; finite element;
D O I
10.1016/j.jbiomech.2006.05.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
A 3-D finite element model (FEM) of the lumbar spine (L1-S1) was used to determine the effect of a large compressive follower pre-load on range of motions (ROM) in all three planes. The follower load modeled in the FEM produced minimal vertebral rotations in all the three planes. The model was validated by comparing the disc compression at all levels in the lumbar spine with the corresponding results obtained by compressing 10 cadevaric lumbar spines (1-S1) using the follower load technique described by Patwardhan et al. [1999. A follower load increases the load-carrying capacity of the lumbar spine in compression. Spine 24(10), 1003-1009]. Further validation of the model was performed by comparing the lateral bending and torsion response without pre-load and the flexion-extension response without pre-load and with an 800 N follower pre-load with those obtained using cadaver lumbar spines. Following validation, the FEM was subjected to bending moments in all three planes with and without compressive follower pre-loads of up to 1200N. Disc compression values and the flexion-extension range of motion under 800 N follower pre-load predicted by the FEM compared well with in vitro results. The current model showed that compressive follower pre-load decreased total as well as segmental ROM in flexion-extension by up to 18%, lateral bending by up to 42%, and torsion by up to 26%. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1326 / 1332
页数:7
相关论文
共 22 条
[21]
WILDER DG, 1989, B HOSP JOINT DIS ORT, V49, P155
[22]
Is it possible to simulate physiologic loading conditions by applying pure moments?: A comparison of in vivo and in vitro load components in an internal fixator [J].
Wilke, HJ ;
Rohlmann, A ;
Neller, S ;
Schultheiss, M ;
Bergmann, G ;
Graichen, F ;
Claes, LE .
SPINE, 2001, 26 (06) :636-642