Gadolinium-loaded nanoparticles: New contrast agents for magnetic resonance imaging

被引:138
作者
Reynolds, CH
Annan, N
Beshah, K
Huber, JH
Shaber, SH
Lenkinski, RE
Wortman, JA
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Dept Radiol, Boston, MA 02215 USA
[2] Rohm & Haas Co, Spring House, PA 19477 USA
[3] Univ Penn, Sch Vet Med, Philadelphia, PA 19104 USA
关键词
D O I
10.1021/ja001426g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We have developed a new class of metal-loaded nanoparticles that have potential as contrast agents for medical imaging. These polymeric materials have a core-shell morphology where the interior is a functionalized polymer, that provides high affinity for a specific metal, and the shell consists of a porous hydrophobic polymer that modulates access to the core. In the present case, the nanoparticles an loaded with Gd3+ to provide contrast in magnetic resonance (MR) imaging. The Gd3+-loaded nanoparticles described in this paper have a diameter of 120 nm and are, therefore, small enough to pass easily through the vasculature. These particles have been shown to reduce relaxation times in vitro, and provide excellent contrast when used to image the heart and gastrointestinal tract in a rat animal model.
引用
收藏
页码:8940 / 8945
页数:6
相关论文
共 43 条
[1]   Polymeric Contrast Agents for Magnetic Resonance Imaging: Synthesis and Characterization of Gadolinium Diethylonetriaminepentaacetic Acid Conjugated to Polysaccharides [J].
Armitage, Frances E. ;
Richardson, David E. ;
Li, King C. P. .
BIOCONJUGATE CHEMISTRY, 1990, 1 (06) :365-374
[2]  
Balkus K.J., 1992, U.S.Patent, V5, P122, Patent No. 5122363
[3]   A study of suspending agents for gadolinium(III)-exchanged hectorite. An oral magnetic resonance imaging contrast agent [J].
Balkus, KJ ;
Shi, JM .
LANGMUIR, 1996, 12 (26) :6277-6281
[4]   Studies of gadolinium(III)-modified hectorite clays as potential oral MRI contrast agents [J].
Balkus, KJ ;
Shi, JM .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (40) :16429-16434
[5]  
Bishop JF, 1995, ACS SYM SER, V615, P205
[6]   RATIONALE AND APPLICATIONS FOR MACROMOLECULAR GD-BASED CONTRAST AGENTS [J].
BRASCH, RC .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :282-287
[7]  
Brasch RC, 1991, MAGN RESON MED, V22
[8]  
BRASCH RC, 1994, Patent No. 9427498
[9]   CARBOHYDRATE CONTRAST AGENTS FOR NUCLEAR MAGNETIC-RESONANCE IMAGING - ENHANCEMENT OF THE RELAXATION OF WATER BY PARAMAGNETIC METAL-COMPLEXES OF POLYSACCHARIDES [J].
BRAYBROOK, JH ;
HALL, LD .
CARBOHYDRATE RESEARCH, 1989, 187 (01) :C6-C8
[10]   SYNTHESIS AND EVALUATION OF PARAMAGNETIC PARTICULATES AS CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING (MRI) [J].
BRAYBROOK, JH ;
HALL, LD .
POLYMER INTERNATIONAL, 1991, 26 (04) :251-259