Quantifying Individual Components of the Timed Up and Go Using the Kinect in People Living With Stroke

被引:40
作者
Vernon, Stephanie [1 ]
Paterson, Kade [2 ]
Bower, Kelly [2 ]
McGinley, Jennifer [2 ]
Miller, Kimberly [2 ]
Pua, Yong-Hao [3 ]
Clark, Ross A. [1 ]
机构
[1] Australian Catholic Univ, Melbourne, Vic, Australia
[2] Univ Melbourne, Melbourne, Vic, Australia
[3] Singapore Gen Hosp, Singapore, Singapore
关键词
kinematic; balance; stroke; gait; gaming; MICROSOFT KINECT; RELIABILITY; VALIDITY; RISK;
D O I
10.1177/1545968314529475
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background. The Microsoft Kinect presents a simple, inexpensive, and portable method of examining the independent components of the Timed Up and Go (TUG) without any intrusion on the patient. Objective. This study examined the reliability of these measures, and whether they improved prediction of performance on common clinical tests. Methods. Thirty individuals with stroke completed 4 clinical assessments, including the TUG, 10-m walk test (10MWT), Step Test, and Functional Reach test on 2 testing occasions. The TUG was assessed using the Kinect to determine 7 different functional components. Test-retest reliability was assessed using intraclass correlation coefficient (ICC), redundancy using Spearman's correlation, and score prediction on the clinical tests using multiple regression. Results. All Kinect-TUG variables possessed excellent reliability (ICC(2,k) > 0.90) except trunk flexion angle (ICC = 0.73). Trunk flexion angle and first step length were nonredundant with total TUG time. When predicting 10MWT and Step Test scores, adding step length into regression models comprising age and total TUG time improved model performance by 7% (P <.01) and 6% (P =.03), respectively. Specifically, an interquartile range increase in first step length (0.19 m) was associated with a 0.15 m/s faster gait speed and 1.8 more repetitions on the Step Test. These effect sizes were comparable to our minimal detectable change scores of 0.17 m/s for gait speed and 1.71 repetitions for the Step Test. Conclusions. Using the Kinect to independently assess the multiple components of the TUG may provide reliable and clinically useful information. This could enable efficient and information-rich large-scale assessments of physical deficits following stroke.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 2011, Cvpr, DOI DOI 10.1109/CVPR.2011.5995316
[2]  
Bernhardt J, 1998, Physiother Res Int, V3, P109, DOI 10.1002/pri.130
[3]   Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables [J].
Clark, Ross A. ;
Bower, Kelly J. ;
Mentiplay, Benjamin F. ;
Paterson, Kade ;
Pua, Yong-Hao .
JOURNAL OF BIOMECHANICS, 2013, 46 (15) :2722-2725
[4]   Validity of the Microsoft Kinect for assessment of postural control [J].
Clark, Ross A. ;
Pua, Yong-Hao ;
Fortin, Karine ;
Ritchie, Callan ;
Webster, Kate E. ;
Denehy, Linda ;
Bryant, Adam L. .
GAIT & POSTURE, 2012, 36 (03) :372-377
[5]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]   Development of a clinical measure of turning for older adults [J].
Dite, W ;
Temple, VA .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (11) :857-866
[7]   FUNCTIONAL REACH - A NEW CLINICAL MEASURE OF BALANCE [J].
DUNCAN, PW ;
WEINER, DK ;
CHANDLER, J ;
STUDENSKI, S .
JOURNALS OF GERONTOLOGY, 1990, 45 (06) :M192-M197
[8]   Expanded Timed Up and Go Test With Subjects With Stroke: Reliability and Comparisons With Matched Healthy Controls [J].
Faria, Christina D. ;
Teixeira-Salmela, Luci F. ;
Silva, Ewerton B. ;
Nadeau, Sylvie .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (06) :1034-1038
[9]   Reliability of gait performance tests in men and women with hemiparesis after stroke [J].
Flansbjer, UB ;
Holmbäck, AM ;
Downham, D ;
Patten, C ;
Lexell, J .
JOURNAL OF REHABILITATION MEDICINE, 2005, 37 (02) :75-82
[10]   Quantitative Falls Risk Assessment Using the Timed Up and Go Test [J].
Greene, Barry. R. ;
O'Donovan, Alan ;
Romero-Ortuno, Roman ;
Cogan, Lisa ;
Scanaill, Cliodhna Ni ;
Kenny, Rose A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (12) :2918-2926