Validation of cartilage volume and thickness measurements in the human shoulder with quantitative magnetic resonance imaging

被引:70
作者
Graichen, H
Jakob, J
von Eisenhart-Rothe, R
Englmeier, KH
Reiser, M
Eckstein, F
机构
[1] Univ Frankfurt, Dept Orthoped Surg, Res Grp Kinemat & Biomech, D-60528 Frankfurt, Germany
[2] Univ Munich, Inst Anat, Musculoskeletal Res Grp, D-80336 Munich, Germany
[3] GSF Neuherberg, Inst Med Informat, D-85764 Oberschleissheim, Germany
[4] Univ Munich, Klinikum Grosshadern, Dept Clin Radiol, D-81377 Munich, Germany
关键词
cartilage; shoulder; magnetic resonance imaging; thickness measurement;
D O I
10.1016/S1063-4584(03)00077-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To validate quantitative magnetic resonance imaging (qMRI) for the assessment of cartilage volume and thickness in thin and curved cartilage layers, such as the shoulder. Methods: Eight shoulder specimens from healthy individuals (aged 31-69 years) were investigated using a 3D gradient echo sequence with selective water excitation. After segmentation with a B-spline Snake algorithm, the cartilage volume and thickness were determined three dimensionally. The cartilage volume data were compared with water displacement of surgically removed tissue, and the thickness with A-mode ultrasound. Results: The glenoid and humeral head cartilage volume from qMRI agreed highly with that from water displacement (systematic difference, +/-1 to +/-3%; absolute difference, 4 to 7%). For the cartilage thickness, the mean systematic difference ranged from -17% (mean cartilage thickness of the glenoid) to +7% (maximal cartilage thickness of the glenoid); the standard error of the estimate was 3.7% for the humeral head, and 6.4% for the glenoid. Conclusions: The applied technique can be used for accurate determination of cartilage volume and thickness in human joints with highly curved and thin cartilage layers, such as the shoulder. In vivo application of this method will depend on the development of efficient surface coils that allow high resolution imaging under in situ conditions. (C) 2003 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:475 / 482
页数:8
相关论文
共 36 条
[1]   The distribution of cartilage thickness within the joints of the lower limb of elderly individuals [J].
Adam, C ;
Eckstein, F ;
Milz, S ;
Putz, R .
JOURNAL OF ANATOMY, 1998, 193 :203-214
[2]   The distribution of cartilage thickness in the knee-joints of old-aged individuals - measurement by A-mode ultrasound [J].
Adam, C ;
Eckstein, F ;
Milz, S ;
Schulte, E ;
Becker, C ;
Putz, R .
CLINICAL BIOMECHANICS, 1998, 13 (01) :1-10
[3]   Quantitative cartilage imaging of the human hind foot: precision and inter-subject variability [J].
Al-Ali, D ;
Graichen, H ;
Faber, S ;
Englmeier, KH ;
Reiser, M ;
Eckstein, F .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (02) :249-256
[4]  
Aspden RM, 1998, MED ENG PHYS, V20, P393
[5]   QUANTITATION OF ARTICULAR SURFACE-TOPOGRAPHY AND CARTILAGE THICKNESS IN KNEE JOINTS USING STEREOPHOTOGRAMMETRY [J].
ATESHIAN, GA ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :761-776
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Burgkart R, 2001, ARTHRITIS RHEUM, V44, P2072, DOI 10.1002/1529-0131(200109)44:9<2072::AID-ART357>3.0.CO
[8]  
2-3
[9]   Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements [J].
Cohen, ZA ;
McCarthy, DM ;
Kwak, SD ;
Legrand, P ;
Fogarasi, F ;
Ciaccio, EJ ;
Ateshian, GA .
OSTEOARTHRITIS AND CARTILAGE, 1999, 7 (01) :95-109
[10]  
ECKSTEIN F, 1992, J ANAT, V180, P425