Prestructured MALDI-MS sample supports have been developed that simplify high-throughput analysis of biomolecules and improve the detection sensitivity. The mass spectrometric sample support is coated with a thin layer of hydrophobic Tenon that carries an array of 200-mu m gold spots, which provide hydrophilic sample anchors. Each transferred sample droplet contacts one anchor, on top of which, after solvent evaporation, the sample is exclusively deposited due to the strongly water repellent nature of the Tenon surface. The initial matrix concentration is kept low, enabling sample up-concentration by more than 2 orders of magnitudes before crystallization commences. As a result, the detection sensitivity is improved as documented by mass spectra recorded from 100 amol of various peptides, 1 fmol of a DNA 20 mer, and 5 fmol of a 130 bp PCR product. Size and spacing of the hydrophilic anchors are optimized for MALDI-MS performance (sample spot size approximate to laser irradiation spot size), for short analysis times (predetermined sample coordinates), and for high throughput sample preparation (sample anchor array according to the 1536 microtiter plate format).
引用
收藏
页码:3436 / 3442
页数:7
相关论文
共 36 条
  • [1] Proteomics: quantitative and physical mapping of cellular proteins
    Blackstock, WP
    Weir, MP
    [J]. TRENDS IN BIOTECHNOLOGY, 1999, 17 (03) : 121 - 127
  • [2] Braun A, 1997, CLIN CHEM, V43, P1151
  • [3] Improved analysis of microsatellites using mass spectrometry
    Braun, A
    Little, DP
    Reuter, D
    MullerMysok, B
    Koster, H
    [J]. GENOMICS, 1997, 46 (01) : 18 - 23
  • [4] DNA sequencing after the Human Genome Project
    Cantor, CR
    Tang, K
    Graber, JH
    Maloney, M
    Fu, DJ
    Broude, NE
    Siddiqi, F
    Koester, H
    Smith, CL
    [J]. NUCLEOSIDES & NUCLEOTIDES, 1997, 16 (5-6): : 591 - 598
  • [5] Influence of matrix solution conditions on the MALDI-MS analysis of peptides and proteins
    Cohen, SL
    Chait, BT
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (01) : 31 - 37
  • [6] COTTRELL JS, 1994, PEPTIDE RES, V7, P115
  • [7] Sequencing exons 5 to 8 of the p53 gene by MALDI-TOF mass spectrometry
    Fu, DJ
    Tang, K
    Braun, A
    Reuter, D
    Darnhofer-Demar, B
    Little, DP
    O'Donnell, MJ
    Cantor, CR
    Köster, H
    [J]. NATURE BIOTECHNOLOGY, 1998, 16 (04) : 381 - 384
  • [8] Gobom J, 1999, J MASS SPECTROM, V34, P105, DOI 10.1002/(SICI)1096-9888(199902)34:2<105::AID-JMS768>3.0.CO
  • [9] 2-4
  • [10] Rapid micro-scale proteolysis of proteins for MALDI-MS peptide mapping using immobilized trypsin
    Gobom, J
    Nordhoff, E
    Ekman, R
    Roepstorff, P
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 169 : 153 - 163