New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury

被引:44
作者
Abbas, MN [1 ]
Mostafa, GAE [1 ]
机构
[1] Natl Res Ctr, Dept Appl Organ Chem, Microanalyt Res Lab, Cairo, Egypt
关键词
mercury; tetrazolium-teriiodomercurate; modified carbon paste electrode; potentiometry;
D O I
10.1016/S0003-2670(02)01520-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new tetrazolium-triiodomercurate-modified carbon paste electrode has been described for the sensitive and selective determination of mercury. The electrode shows a stable, near-Nernstian response for 1 x 10(-3) to 6 x 10(-6) M [HgI3](-) at 25 degreesC over the pH range of 4.0-9.0, with an anionic slope of 55.5 +/- 0.4 mV. The lower detection limit is 4 x 10(-6) M with a fast response time of 30-50 s. Selectivity coefficients of a number of interfering anions and iodo complexes of some metal ions have been estimated. The interference from many of the investigated ions is negligible. The determination of 1-200 mug/ml of mercury in aqueous solutions shows an average recovery of 98.5% and a mean relative standard deviation of 1.6% at 50.0 mug/ml. The direct determination of mercury in spiked wastewater, metal amalgams and dental alloy gave results that compare favorably with those obtained by the cold vapor atomic absorption spectrometric method. Potentiometric titration of mercury and phenylmercury acetate with standard potassium iodide has been monitored using the developed triiodomercurate-carbon paste electrode (CPE) as an end point indicator electrode. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:329 / 335
页数:7
相关论文
共 25 条
[1]   PVC membrane ion selective electrode for the determination of pentachlorophenol in water, wood and soil using tetrazolium pentachlorophenolate [J].
Abbas, MN ;
Mostafa, GAE ;
Homoda, AMA .
TALANTA, 2001, 55 (03) :647-656
[2]  
BEMEJOBARRERA P, 1999, ANAL CHIM ACTA, V398, P263
[3]   Data processing technique for mercury determination by total-reflection X-ray fluorescence, using amalgamation with gold [J].
Bennun, L ;
Gillette, VH ;
Greaves, ED .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (09) :1291-1301
[4]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[5]  
El-Sayed AY, 1998, ANAL LETT, V31, P1905
[6]   A time-based flow injection cold vapor atomic absorption spectrometry system with on-line microwave sample pre-treatment for the determination of inorganic and total mercury in urine [J].
Gallignani, M ;
Bahsas, H ;
Brunetto, MR ;
Burguera, M ;
Burguera, JL ;
de Peña, YP .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :57-67
[7]   SPECTROPHOTOMETRIC DETERMINATION OF SOME PHARMACEUTICALLY IMPORTANT NITRO-COMPOUNDS IN THEIR DOSAGE FORMS [J].
HASSAN, SM ;
BELAL, F ;
ELDIN, MS ;
SULTAN, M .
ANALYST, 1988, 113 (07) :1087-1089
[8]   Novel mercury (II) ion-selective polymeric membrane sensor based on ethyl-2-benzoyl-2-phenylcarbamoyl acetate [J].
Hassan, SSM ;
Saleh, MB ;
Gaber, AAA ;
Mekheimer, RAH ;
Kream, NAA .
TALANTA, 2000, 53 (02) :285-293
[9]   Determination of mercury in gold bullion by flame and graphite furnace atomic absorption spectrometry [J].
Hinds, MW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1063-1068
[10]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22