Comparison of different iodine concentration contrast media in perfusion computed tomography of the brain - Is high iodine concentration useful?

被引:7
作者
Kloska, Stephan P.
Fischer, Tobias
Nabavi, Darius G.
Wessling, Johannes
Dittrich, Ralf
Fischbach, Roman
Seidensticker, Peter
Ringelstein, E. Bernd
Heindel, Walter
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Neurol, D-48149 Munster, Germany
[3] Schering AG, Global Clin Dev Diagnost, Berlin, Germany
关键词
cerebral ischemia; perfusion; x-ray; computed; tomography; contrast media;
D O I
10.1097/RLI.0b013e318042b608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To investigate maximum enhancement and visual map quality in cerebral perfusion computed tomography (PCT) with variation of iodine concentration of contrast media (CM). Materials and Methods: Two groups of 45 patients each, underwent PCT with either 370 mg iodine/mL (30 mL; 6 mL/s) or 300 mg iodine/mL (40 mL; 8 mL/s) CM, respectively, and similar total iodine dose. Parenchymal and vascular enhancement as well as contrast-to-noise ratio of superior sagittal sinus was measured on PCT source images. PCT maps were rated visually with dichotomized scale for diagnostic quality. Results: Enhancement and contrast-to-noise ratio of the superior sagittal sinus was significantly higher for the 370 mg iodine/mL protocol (P < 0.0002 and P < 0.007), whereas parenchymal enhancement was not significantly different. Diagnostic quality of PCT maps did not differ between both protocols (P < 0.557). Conclusions: PCT using 370 mg iodine/mL CM can be reliably performed with reduced injection rate and less total volume enabling smaller diameter of intravenous canula compared with 300 mg iodine/mL CM.
引用
收藏
页码:564 / 568
页数:5
相关论文
共 34 条
[11]   Acute stroke assessment with CT: Do we need multimodal evaluation? [J].
Kloska, SP ;
Nabavi, DG ;
Gaus, C ;
Nam, EM ;
Klotz, E ;
Ringelstein, EB ;
Heindel, W .
RADIOLOGY, 2004, 233 (01) :79-86
[12]   Perfusion measurements of the brain:: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke [J].
Klotz, E ;
König, M .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :170-184
[13]   Iodine delivery rate of different concentrations of iodine-containing contrast agents with rapid injection [J].
Knollmann, F ;
Schimpf, K ;
Felix, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06) :880-884
[14]   Perfusion CT of the brain: Diagnostic approach for early detection of ischemic stroke [J].
Koenig, M ;
Klotz, E ;
Luka, B ;
Venderink, DJ ;
Spittler, JF ;
Heuser, L .
RADIOLOGY, 1998, 209 (01) :85-93
[15]   Image quality in CT perfusion imaging of the brain [J].
Koenig, Matthias ;
Bueltmann, Eva ;
Bode-Schnurbus, Lucas ;
Koenen, Dirk ;
Mielke, Eckhart ;
Heuser, Lothar .
EUROPEAN RADIOLOGY, 2007, 17 (01) :39-47
[16]   Cerebral perfusion CT -: theoretical aspects, practical implementation and clinical experience in acute ischemic stroke. [J].
König, M ;
Klotz, E ;
Heuser, L .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (03) :210-218
[17]   Imaging viable brain tissue with CT scan during acute stroke [J].
Meuli, RA .
CEREBROVASCULAR DISEASES, 2004, 17 :28-34
[18]   Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media [J].
Miles, KA .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M117-M120
[19]   Imaging of acute stroke [J].
Moonis, M ;
Fisher, M .
CEREBROVASCULAR DISEASES, 2001, 11 (03) :143-150
[20]   CT assessment of cerebral perfusion: Experimental validation and initial clinical experience [J].
Nabavi, DG ;
Cenic, A ;
Craen, RA ;
Gelb, AW ;
Bennett, JD ;
Kozak, R ;
Lee, TY .
RADIOLOGY, 1999, 213 (01) :141-149