How the NPX data format handles EEG data acquired simultaneously with fMRI

被引:12
作者
Bianchi, Luigi
Quitadamo, Lucia Rita
Marciani, Maria Grazia
Maraviglia, Bruno
Abbafati, Manuel
Garreffa, Girolamo
机构
[1] IRCCS Fdz, Unita Neurofisiopatol, I-00179 Rome, Italy
[2] Univ Roma Tor Vergata, Neurosci Dept, I-00133 Rome, Italy
[3] MARBILab, Enrico Fermi Ctr, I-00179 Rome, Italy
关键词
file format; data format; XML;
D O I
10.1016/j.mri.2007.03.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
There is a growing interest in combining EEG and (f)MRI data as they provide complementary information: EEG is characterized by a high temporal resolution but poor spatial one, while fMRI is characterized by a high spatial resolution but low temporal one. However, while a standard file format for storing EEG data is available since over a decade, it does not fulfill the needs of modem protocols and devices such as those involved in simultaneous EEG and fMRI recordings. The main reasons are the limited bit resolution, some difficulties encountered in handling and storing acquisition events or trace markers for off-line analyses and the impossibility to add some protocol-specific information that is not considered in the actual data formats. This, among others, hinders the release of free analysis software and makes it difficult to share data across different laboratories as every research unit develops its own tools according to its needs, stores data in proprietary formats and a lot of time is spent building software applications for converting data from one format to another. The NPX (NeuroPhysiological signals in eXtensible Markup Language) data format was defined to overcome these and other limitations, and here its main characteristics are reported as well as how some typical problems occurring in simultaneous EEG-fMRI recordings are also treated. Many tools based on the NPX technology can be freely downloaded, including a tool for removing artifacts occurring during simultaneous EEG-fMRI recordings. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1011 / 1014
页数:4
相关论文
共 7 条
  • [1] Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    Allen, PJ
    Polizzi, G
    Krakow, K
    Fish, DR
    Lemieux, L
    [J]. NEUROIMAGE, 1998, 8 (03) : 229 - 239
  • [2] Stepping stone sampling for retrieving artifact-free electroencephalogram during functional magnetic resonance imaging
    Anami, K
    Mori, T
    Tanaka, F
    Kawagoe, Y
    Okamoto, J
    Yarita, M
    Ohnishi, T
    Yumoto, M
    Matsuda, H
    Saitoh, O
    [J]. NEUROIMAGE, 2003, 19 (02) : 281 - 295
  • [3] Bianchi L, 2003, METHOD INFORM MED, V42, P104
  • [4] Simultaneous EEG-fMRI acquisition:: how far is it from being a standardized technique?
    Garreffa, G
    Bianciardi, M
    Hagberg, GE
    Macaluso, E
    Marciani, MG
    Maraviglia, B
    Abbafati, M
    Carnì, M
    Bruni, I
    Bianchi, L
    [J]. MAGNETIC RESONANCE IMAGING, 2004, 22 (10) : 1445 - 1455
  • [5] A SIMPLE FORMAT FOR EXCHANGE OF DIGITIZED POLYGRAPHIC RECORDINGS
    KEMP, B
    VARRI, A
    ROSA, AC
    NIELSEN, KD
    GADE, J
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (05): : 391 - 393
  • [6] European data format 'plus' (EDF+), an EDF alike standard format for the exchange of physiological data
    Kemp, B
    Olivan, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2003, 114 (09) : 1755 - 1761
  • [7] EEG source imaging
    Michel, CM
    Murray, MM
    Lantz, G
    Gonzalez, S
    Spinelli, L
    de Peralta, RG
    [J]. CLINICAL NEUROPHYSIOLOGY, 2004, 115 (10) : 2195 - 2222